Temperature Settings On The Computer Board - A.O. Smith 910 Installation Manual And Owner's Manual

On-demand gas tankless water heater
Hide thumbs Also See for 910:
Table of Contents

Advertisement

<Information mode>
You can get some information about the water heater condition by pressing the "INFO" button. The following information will
be displayed seqentially by pressing the "INFO" button.
Inlet water temperature
I
N
L / M G / M
O U T
FLOW
<Unit conversion mode>
The remote controller has a function that can change units of temperature and flow rate from "°F and GPM" to "°C
and Liter/min".
To change the remote controller's unit mode
1. Turn off power to the remote controller by pressing the "ON/OFF" button.
2. Simultaneously press and hold both the "HOT" and "COLD" buttons for at least 5 seconds. Then make sure "1"
(or "0" for Easy-Link System or Multi-Unit System) is displayed on remote controller.
3. Press the "TIME" button. Make sure "OFF" and "F1" are displayed on remote controller.
4. Press the "HOT" button or the "COLD" button to set display to "F3".
5. Press the "INFO" button and make sure "
6. Press the "HOT" button or the "COLD" button to set display to "
7. Simultaneously press both the "BUZZER" button and the "INFO" button to fix the setting.
8. Make sure that the display is no longer blinking.
9. Press the "ON/OFF" button to finish the setting.
10. Turn on power to the remote controller by pressing the "ON/OFF" button again.
These images show the procedure's results on the display (listed in sequential order).
I
N
L/ M G / M
O U T
FLOW
I
N
L / M G / M
OR
O U T
FLOW
I
N
L/ M G / M
O U T
FLOW
There are eight preset temperatures that you can select by changing the DIP switch settings on the computer board.
The temperature has been preset at the factory to 120 °F (50 °C).
If you desire to change the set temperature with DIP switches on the computer board, refer to the diagram below
and observe the warnings.
If you desire a hot water temperature other than the eight preset settings, purchase the optional temperature
remote controller 100112155 (TM-RE30).
With this optional remote controller, you can set the temperature from 100 °F to 185 °F (38 °C to 85 °C) in various
increments.
To change the DIP switch settings for set temperature, locate the lower bank
of DIP switches at the bottom of the center computer board.
DO NOT adjust any other DIP switches .
Turn off the power supply to the water heater before changing the DIP switch
WARNING
settings.
Failure to observe this warning could result in carbon monoxide poisoning or death.
Temperature settings ( Lower bank of DIP switches)
1
2
3
100 °F (38 °C)
ON
1
2
3
115 °F (46 °C)
ON
1
2
3
120 °F (50 °C)
DEFAULT
ON
1
2
3
135 °F (57 °C)
ON
Outlet water temperature
I
N
L / M G / M
O U T
FLOW
°F
" blinks.
I
N
L / M G / M
O U T
FLOW
4
5
6
7
8
145 °F (63 °C)
4
5
6
7
8
155 °F (68 °C)
4
5
6
7
8
165 °F (74 °C)
4
5
6
7
8
185 °F (85 °C)
38
Water flow
I
N
L / M
G / M
O U T
FLOW
°C
".
I
N
L / M G / M
I
N
O U T
O U T
FLOW
FLOW
Blinks
Blinks
Lower bank of DIP switches
on the center computer board
1
2
3
4
5
6
7
8
ON
1
2
3
4
5
6
7
8
ON
1
2
3
4
5
6
7
8
ON
1
2
3
4
5
6
7
8
ON
Page
Finish
I
N
L / M G / M
O U T
FLOW
L / M G / M
I
N
L / M G / M
O U T
FLOW

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

910 asme

Table of Contents