Roper ELECTRIC DRYER RES7646J Dimensions
Roper ELECTRIC DRYER RES7646J Dimensions

Roper ELECTRIC DRYER RES7646J Dimensions

Electric dryer

Advertisement

Quick Links

®
PRODUCT MODEL NUMBERS
RES7646J
REX4625E
RES7646K
REX4634J
RES7648E
REX4634K
RES7648J
REX4635E
RES7648K
REX5634J
REX3614J
REX5634K
REX3614K
REX5635E
REX3615E
Electrical: A four-wire or three-wire, single phase,
120/240-volt, 60-Hz, AC-only, electrical supply is
required on a separate 30-ampere circuit, fused on
both sides of the line. Use 10 gauge solid copper
wire. A time-delay fuse or circuit breaker is
recommended.
Exhaust venting: Exhaust your dryer to the
outside. Four-inch diameter vent is required. Rigid
or flexible metal exhaust vent must be used. Do Not
use plastic or metal foil vent. Exhaust outlet hood
must be at least 12 inches from the ground or any
object that may be in the path of the exhaust.
RECESSED AREA AND CLOSET INSTALLATION
Recommended/Minimum
Back
Sides
Top
Recessed
5"/0"
1"/0"
18"/18"
Closet
5"/4"
1"/0"
18"/18"
front view
Recessed
18"
area
0" *
0" *
*Wall, door and floor molding may require
additional spacing.
EXHAUST VENTING
Preferred
4"
When you have a 4" hood
Maximum length of 4"
diameter metal vent
Number of
Rigid
Flexible
90° elbows
(fully extended)
0
64 ft.
36 ft.
1
54 ft.
31 ft.
2
44 ft.
27 ft.
3
35 ft.
25 ft.
4
27 ft.
23 ft.
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Electric Dryer
OVERALL DIMENSIONS
42-3/8"*
*from floor with dryer
feet extended 1 inch
Closet confined area
Front
If a closet door is installed: The minimum unobstructed air
openings are required. Louvered doors with equivalent air
1"/1"
openings are acceptable.
front view
**
48 sq. in.
**
24 sq. in.
** Minimum top and bottom air openings for closet door.
*** External exhaust elbow requires additional space.
Acceptable
4"
When you have a 2-1/2" hood
Maximum length of 4"
diameter metal vent
Number of
Rigid
90° elbows
0
58 ft.
1
48 ft.
2
38 ft.
3
29 ft.
4
21 ft.
terminal
block cover
power supply
cord/cable
opening
14-1/2"
6"*
dryer exhaust
vent
28" max.
side view
3"
14"
max.
closet
door
***
4"
3"
1"
Select the route that will provide the straightest and most direct path
outdoors. Plan the installation to use the fewest number of elbows and
turns. Avoid making 90° turns.
When using elbows or making turns, allow as much room as possible.
Bend flexible metal vent gradually to avoid kinking.
2-1/2"
Determine vent length
1. See the exhaust vent length chart that matches your type hood for the
maximum vent lengths you can use.
Do not use vent runs longer than specified in exhaust vent length charts.
Flexible
(fully extended)
2. Determine the number of elbows you will need.
28 ft.
3. In the column listing the type of metal vent you are using (rigid or
23 ft.
flexible), find the maximum length of metal vent on the same line as the
number of elbows.
19 ft.
17 ft.
The maximum length using a 2" x 6" rectangular vent with 2 elbows and
15 ft.
a 2-1/2" exhaust hood is 8 ft.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
DOOR CLEARANCE DIMENSIONS
22-3/4"
side-swing door (reversible)
22-3/4"
29"
Large side-swing
door (reversible)
15-1/4"
Small side-swing door
25-5/8"
13-3/4"
Extra-large hamper door
3-7/8"
19-1/8"
22-3/4"
Super-large
7"
17-3/4"
22-3/4"
8-1/4"
15-1/4"
15-1/4"
8-3/4"
13-3/4"
Ref. 3397618