2-3 Timing Chart

This section of the service manual describes the timing that the computer industry recognizes as standard
for computer-generated video signals.
Mode
IBM
VGA2/70 Hz
VGA3/60 Hz
720 x 400
Timing
fH (kHz)
31.469
A µsec
31.777
B µsec
3.813
C µsec
1.907
D µsec
25.422
E µsec
0.636
fV (Hz)
70.087
O msec
14.268
P msec
0.064
Q msec
1.080
R msec
12.711
S msec
0.413
Clock
Frequency
28.322
(MHz)
Polarity
H.Sync
Negative
V.Sync
Positive
Remark
Separate
Separate Sync
Horizontal
Video
Video
C
D
E
C
D
E
Sync
Sync
Sync
B
B
A
A
A : Line time total
C : Back porch
E : Front porch
PN19MT/MO/IO
x178/19P2
Table 2-1. Timing Chart
640/85 Hz
800/85 Hz
640 x 480
640 x 480
800 x 600
31.469
43.269
31.778
23.111
3.813
1.556
1.907
2.222
25.422
17.778
0.636
1.556
59.940
85.008
16.683
11.764
0.064
0.671
1.048
0.578
15.253
11.093
0.318
0.023
25.175
36.000
Negative
Negative
Negative
Negative
Separate
Separate
Separate
Vertical
Video
Video
Q
Q
R
R
S
S
Sync
Sync
Sync
P
P
P
O
O
O
B : Horizontal sync width
D : Active time
VESA
1024/85 Hz
1280/75 Hz
1280 x 1024
1024 x 768
53.674
68.677
18.631
14.561
1.138
1.016
2.702
2.201
14.222
10.836
0.569
0.508
85.061
84.997
11.756
11.765
0.056
0.044
0.503
0.524
11.179
11.183
0.019
0.015
56.250
94.500
135.000
Positive
Positive
Positive
Positive
Positive
Positive
Separate
Separate
O : Frame time total
Q : Back porch
S : Front porch
2 Product Specifications
1280/85 Hz
1600/75 Hz
1280 x 1024
1600 x 1200
79.976
91.146
93.750
12.504
10.667
10.971
1.067
1.016
1.837
1.422
9.481
8.127
0.119
0.406
75.025
85.024
75.000
13.329
11.761
13.333
0.038
0.033
0.475
0.483
12.804
12.800
11.235
0.013
0.011
157.500
202.500
Positive
Positive
Positive
Positive
Separate
Separate
P : Vertical sync width
R : Active time
0.948
1.501
7.901
0.316
0.032
0.491
0.011