Pioneer AVIC-F900BT/XS/RE Service Manual page 40

Navigation av system
Table of Contents

Advertisement

1
ASMAX check
ASMAX value shows the value of RF level.
A
Status: [Foucs closed] of TEST MODE
No.
1
2
B
In this case, the value is displayed for a split second.
When you tried to perform [FOCS CLOSE],
the display will charge automatically in the following order.
[1FFF0000]->[FEMAX]->[FE MIN]->[AS MAX]->
[ENV MAX]->[FE normal]->[Spindle gain]->
[TEMAX]->[TEMIN]
C
Watch carefully the value of ASMAX.
Error rate check
Status: [Tracking Closed] of TEST MODE
No.
1
D
2
3
E
F
40
1
2
Disc
Check Point
8 digits value of
more than
ASMAX
GGV1025
on display
8 digits value of
more than
TCD-782
ASMAX
on display
->[20000000]
Disc
Check Point
GGV1025
ID: 40000
1.000E-03
GGV1025
ID: 200000
1.000E-03
TCD-782 ID: HOME Position
2.500E-03
AVIC-F900BT/XS/EW5
2
3
Threshold
Remarks:
Only four last digits are
displayed according to
0000 0600
the product.
Only four last digits is
displayed according to
the product.
0000 0C00
Threshold
Remarks:
less than
less than
less than
3
4
4

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Avic-f900bt/xs/ew5