Installation Instructions
Pin assignment
Pin assignment for the
100-240 V, 50-60 Hz power
supply unit
Pin assignment for the
24 V
power supply unit
DC
Fitting the connector to the
cable
Applying the strain relief
14

Pin assignment and cable requirements

There is an adhesive label with the pin assignments on the top of the
female plug connector. The minimum permitted conductive cross-
section is 1.5 mm², fused for 10 A (AWG 16).
Industrial PCs with 100-240 V
5 4
3
2
1
Industrial PCs with 24 V
5 4
2
3
1
The plug is fitted to the cable as follows:
1. Strip insulation from the cable ends. Follow the technical data for
the female plug connector in the above table!
2. Push the conductors into their mountings, simply by pushing them
in as indicated on the pin assignment label.
3. Push the lower part (part A) of the strain relief housing onto the top
of the female plug connector until it snaps into place.
4. Relieve the strain on the supply cable by fixing it in place with the
cable clamp (part C) and fixing screws (part D).
Fix the upper part (part B) of the strain relief housing by snapping it onto
the lower part.
, 50-60 Hz power supply unit
AC
Pin
Function
1
N
2
L
3
4
not used
5
not used
power supply unit
DC
Pin
Function
1
+
2
-
3
4
not used
5
not used
100 – 240V
AC
Power supply
24V
DC
Power supply
C6240