Open the valve of the gas bottle, push in the right hand control knob on
the cooler and keep it pushed for approx. 20 seconds (in order to get the
air inside the gas system removed). With the button still pushed in turn the
knob anti-clockwise to the max position to to get the gas flame ignited by a
spark.
Make sure that a flame is visible at the burner (Fig. 7), wait for another 15
seconds until the red needle on the gas gauge is visible and then release the
knob (Fig. 8).
It is possible that this procedure needs to be repeated a couple of times,
especially when the cooler has not been in use for a long period of time.
Wait some minutes between every ignition. The cooler is equipped with
a safety pilot. In case the flame goes out the gas supply will be stopped
automatically.
For switching off close first the valve of the gas bottle and then turn the gas
control knob off by turning it clockwise as far as it will go.
Useful Hints: Put food and beverages in an appropriate container inside the
cooler and store them in a way so that the air can circulate freely. Do not put
warm or hot food and beverages inside the cooler.

5. Maintenance and Storage

The build-up of ice inside the cooler decreases the cooling performance. To remove the ice do not use any sharp objects but
switch off the cooler and defrost it. It is recommended to defrost the cooler regularly. In case the appliance is not in use for
a long period of time, disconnect from any source of power or gas and leave the lid slightly open in order to let air circulate
inside the cooling compartment.
A handy tip: If after such a period the cooler does not cool down, switch off again leave it turned upside down. Make sure
that the connection cables are disconnected. After 2 to 3 hours put it upright again, re-connect and switch on. If there still
should not be any cooling function repeat this procedure.
Important Hint: Maintenance and repairs, especially on the cooling aggregate and on the gas burner can only be done by
qualified service engineers.

Hints for operating errors and faults:

Before contacting the supplier check the following points:
• Is the cooler placed in a suitable location with sufficient ventilation?
• Is the appliance standing upright on a flat horizontal surface?
• Is the power supply working correctly?
• Check the connection cords for defects.
• Is the plug properly placed in the socket?
• Is the thermostat switched on for mains operation (AC 230V)?
• Has the gas control knob been pushed long enough?
• Is the gas control knob placed in max position?
• Does the gas bottle contain enough gas?
• Is the cooler connected to different energy sources at the same time?
• Have warm or hot products been put inside the cooler?
• Have too many products been put inside the cooler?
• Can the air circulate freely inside the cooler?
Despite considering these points if no satisfying function can be achieved, please contact the supplier.