Warning; Water Quality; Installation; Location - Rheem 316937A Owner's Manual And Installation Instructions

Classic series powder coated and stainless steel
Table of Contents

Advertisement

LAZER BOILING WATER UNIT
INSTALLATION AND OWNERS GUIDE
Thank you for choosing our Lazer
Boiling Water Unit. Please take a few
minutes to read this booklet because it
contains important information about
the correct installation and operation of
your Lazer unit.
1.

WARNING:

This Lazer unit produces boiling water
(third degree burns may occur) and care
should be taken at all times when using
it. This unit is not intended for use by
infirm persons and young children
should be supervised to ensure that
they do not play with the unit.

2. WATER QUALITY

Caution is suggested if the Boiling
Water Unit is to be connected to a water
supply with a high content of silica or
calcium. Water supplies of this nature
may
be
detrimental
operation and may cause the warranty
to become void. For further information
relating to the guidelines of water
quality, contact your local Rheem office
for advice.

3. INSTALLATION

This boiling water unit shall be installed
by a qualified service person. The
installation must comply with AS/NZS
3500.4 and all relevant statutory and
local body requirements of the state in
which the Boiling Water Unit is installed.
A. LOCATION
This
unit
is
designed
installation only.
B. OPENING THE UNIT
To remove the jacket from models 3, 5,
7.5 & 10 L remove the 4 retaining
screws at the top and bottom and pull
the jacket forward. For models 15, 25
and 40 L unscrew the lid at the top and
service plate on the left hand side.
to
the
unit's
for
interior
C. MINIMUM CLEARANCES
For ventilation reasons, all units require a
minimum clearance of 50mm on all sides.
For ease of servicing (where there is
sufficient space) we recommend 300mm
clearance from the top of all units. For
element
replacement
recommend clearance of 150mm from the
right hand side of 3 to 10 litre units and
300mm from the left hand side of the 15 to
40 litre units.
D. MOUNTING
The Lazer when installed is suspended
from mounting screws located into keyhole
slots
at
the
(refer
to
the
Specification on page 6).
Be sure that the mounting screws are
securely inserted into the keyhole slots.
The screws MUST be anchored in such a
way, that they will hold the weight of the
unit when filled with water, (refer to the
specification table on page 5).
WARNING:
Before drilling into the wall make sure that
the screw positions avoid any pipe-work or
electrical cables. Allow 4 mm clearance
between the screw head and the wall for
locating the unit.
E. WATER SUPPLY CONNECTION
Cold mains pressure water (refer to
specification table on page 5 for minimum
water pressures) must be piped and
connected to the ½" BSP inlet fitting
located on the left hand side underneath
the unit. An accessible isolating valve must
be installed near the unit.
This unit contains an inlet strainer on the
water inlet connection (refer to figure 1). To
ensure continuing satisfactory operation, it
is suggested that the inlet strainer be
serviced every six months by a qualified
service person. Where poor water quality is
present it is recommended to install an
additional auxiliary filter.
reasons
back
of
the

Mounting

Dimension
we
unit
3.