Rheem RS47-21BP Use & Care Manual page 39

Passive solar water heating systems
Hide thumbs Also See for RS47-21BP:
Table of Contents

Advertisement

Frames continued.....
Variations for Shallow Pitch or Flat Deck Roofs
Flashing and Roof Penetrations
39
On shallow pitch roofs (less than 8°) of
metal or fibreboard materials, the frame
may be installed without using the pipe
legs, provided that the inclination of the
solar collector remains greater than 8°.
Flashing of roof penetrations must meet
the requirements of the local authorities.
Suggested methods are shown below.
On flat roofs, the assembled frame may
be installed without the baseplates.
Provided the roof material is structurally
suited, the frame may be bolted directly
to it.
1965
Alternative:
Clamp flashing cone in place with
stainless steel hose clamp and seal to pipe
leg with silicone mastic.
Pipe Leg
Less than 8.0°
Overflashing Cone
(Fixed to pipe leg.)
Flashing sheet