Main Unit Modifications - Vertex Standard VX-6000V Service Manual

Hide thumbs Also See for VX-6000V:
Table of Contents

Advertisement

The PA Unit have been discontinued. Therefore, the PA Unit is not possible to order as the repair parts, and
replaced with the PA-2 Unit.
When replacing the PA Unit to PA-2 Unit, you must be modified the MAIN Unit as following.
Delete the Gusket (RA0530900). This part is no longer needed.
Delete the Shield Cover (RA0124501). This part is no longer needed.
Replace the Power Module IC (G1094314  G1095439: RA30H1317M1A-122).
Add the Chip Resistor (J24205102) between Pin 1 and Pin 2 of Q1017 (Power Module IC).
Add the Jumper wire (T51508002) between the Pin 8 of J1001 and Pin 8 of Q1007.
VX-6000 VHF Service Manual

MAIN Unit Modifications

Delete the Gusket
Delete the Shield Cover
Replace the Power Module IC
RA30H1317M1A-122
(P/N: G1095439)
Add the Chip Resistor
1 k-ohm, 1/10 W
(P/N: J24205102)
Add the Jumper Wire
AWG28, 80 mm
(P/N: T51508002)
4-2

Advertisement