Download Print this page
Vertex Standard VX-410 Series Operating Manual
Vertex Standard VX-410 Series Operating Manual

Vertex Standard VX-410 Series Operating Manual

Controls & connectors
Hide thumbs Also See for VX-410 Series:

Advertisement

Quick Links

VX-410/-420 Series
Operating Manual
Controls & Connectors
LED Indicator
Glows Green
Monitor on (or Side 1, 2 switch is activated : VX-410 series only)
Blinking Green Busy Channel (or SQL off)
Transmitting
Glows Red
Blinking Red
Battery Voltage is low
Yellow
Receiving a Selective Call
CH ( Channel ) Selector
Antenna
VOL/PWR Knob
Push To Talk
( PTT ) Switch
MIC/SP Jack
( External Mic/Earphone )
Microphone
Side 1 Switch
Speaker
Side 2 Switch
LCD
(VX-420 series)
16 KEY
(VX-420 series)
Battery Pack Latch
E
C
0
5
0
U
1
0
SAFETY TRANING INFORMATION
This Radio has been tested and complies with the Federal Communi-
cations Commission (FCC) RF exposure limits for Occupational Use/
Controlled exposure environment. In addition, it complies with the
following Standards and Guidelines:
Ì FCC 96-326, Guidelines for Evaluating the Environmental Effects
of Radio-Frequency Radiation.
Ì FCC OET Bulletin 65 Edition 97-01 (1997) Supplement C, Evalu-
ating Compliance with FCC Guidelines for Human Exposure to
Radio Frequency Electromagnetic Fields.
Ì ANSI/IEEE C95.1-1992, IEEE Standard for Safety Levels with Re-
spect to Human Exposure to Radio Frequency Electromagnetic
Fields, 3kHz to 300 GHz.
Ì ANSI/IEEE C95.3-1992, IEEE Recommended Practice for the Mea-
surement of Potentially Hazardous Electromagnetic Fields-RF and
Microwave.
WARNING:This radio generates RF electromagnetic energy dur-
ing transmit mode. This radio is designed for and classified as
Occupational Use Only, meaning it must be used only during the course
of employment by individuals aware of the hazards, and the ways to
minimize such hazards. This radio is not intended for use by the Gen-
eral Population in an uncontrolled environment.
CAUTION:To ensure that your expose to RF electromagnetic
energy is within the FCC allowable limits for occupational use,
always adhere to the following guidelines:
H This radio is NOT approved for use by the general population
in an uncontrolled environment. This radio is restricted to oc-
cupational use, work related operations only where the radio
operator must have the knowledge to control its RF exposure
conditions.
H When transmitting, hold the radio in a vertical position with its
microphone 1 to 2 inches (2.5 to 5 cm) away from your mouth
and keep the antenna at least 1 inch (2.5cm) away from your
head and body.
Before You Begin
Battery Pack Installation and Removal
Ì To install the battery, hold the transceiver with your left hand,
so your palm is over the speaker and your thumb is on the top
of the belt clip. Insert the battery pack into the battery com-
partment on the back of the radio while tilting the Belt Clip
outward, then close the Battery Pack Latch until it locks in
place with a "Click."
Insert the Battery Pack
Close the Battery Pack Latch
Ì To remove the battery, turn the radio off and remove any pro-
tective cases. Open the Battery Pack latch on the bottom of
the radio, then slide the battery downward and out from the
radio while holding the Belt Clip.
Caution!
Do not attempt to open any of the rechargeable Ni-Cd
packs, as they could explode if accidentally short-circuited.
Low Battery Indication
Ì As the battery discharges during use, the voltage gradually
becomes lower. When the battery voltage becomes to low,
substitute a freshly charged battery and recharge the depleted
pack. The TX/BUSY indicator on the top of the radio will
blink red when the battery voltage is low.
Ì Avoid recharging Ni-Cd batteries often with little use between
charges, as this can degrade the charge capacity. We recom-
mend that you carry an extra, fully-charged pack with you so
0
the operational battery may be used until depletion (this "deep
cycling" technique promotes better long-term battery capac-
ity).
H The radio must be used with a maximum operating duty cycle
not exceeding 50 %, in typical Push-to-Talk (PTT) configura-
tions. DO NOT transmit for more than 50 % of total radio use
time (50 % duty cycle). Transmitting more than 50 % of the
time can cause FCC RF exposure compliance requirements to
be exceeded.
The radio is transmitting when the red LED on the top of the
radio is illuminated. You can cause the radio to transmit by press-
ing the PTT button or by using the VOX headset, model VC-25.
H DO NOT transmit when the radio is used in Body Worn con-
figuration with the following accessory: belt-clip.
It must be used ONLY for (1) there is a 4 cm distance from the
body during transmitting, (2) monitoring purposes, using the
speaker only and (3) for carrying purposes.
H Always use Vertex Standard authorized accessories.
The information listed above provides the user with the information
needed to make him or her aware of RF exposure, and what to do to
assure that this radio operates with the FCC RF exposure limits of this
radio.
Electromagnetic Interference/Compatibility
During transmissions, this radio generates RF energy that can pos-
sibly cause interference with other devices or systems. To avoid
such interference, turn off the radio in areas where signs are posted
to do so.
Do not operate the transmitter in areas that are sensitive to electro-
magnetic radiation such as hospitals, health care facilities, aircraft,
and blasting sites.
FCC LICENSE INFORMATION
This radio operates on communications frequencies which are sub-
ject to FCC (Federal Communications Commission) Rules and
Regulations. FCC Rules require that all operators using Private
Land Mobile radio frequencies obtain a radio license before oper-
ating their equipment.
Preliminary Steps
Ì Install a charged battery pack onto the transceiver, as described
previously.
Ì Screw the supplied antenna onto the Antenna jack. Never at-
tempt to operate this transceiver without an antenna connected.
Ì If you have a Speaker/Microphone, we recommend that it not
be connected until you are familiar with the basic operation
of the VX-410/-420.
Operation Quick Start
Ì Turn the top panel's VOL/PWR
knob clockwise to turn on the ra-
dio on.
Ì Turn the top panel's CH selector
knob to choose the desired oper-
ating channel.
Ì Rotate the VOL/PWR knob to set
the volume level. If no signal is
present, press and hold in the Soft
key assigned to "MONITOR" for
more than 1 seconds; background
noise will now be heard, and you
may use this to set the VOL/PWR
knob for the desired audio level.
Display Icons & Indicators
VX-420 Only
"Call" indicator
: "Scan" is activated
: "Priority Scan" is activated
Receiver Monitor
"Dual Watch" is activated
"Talk-Around" is enabled
"Voice Message" received
Group "A"
"Encryption" is enabled
Group "B"
Priority Channel
8 Character Alpha-numeric Display
Low Transmit Power Mode "ON"
Notice !
There are no owner-serviceable parts inside the trans-
ceiver. All service jobs must be referred to an authorized
VERTEX STANDARD Service Representative. Consult
your Authorized VERTEX STANDARD Dealer for in-
stallation of optional accessories.
Operation
Ì Press and hold in the Soft key as-
signed to "MONITOR" for more
than 1 seconds (or press the
MONITOR key twice) to quiet
the noise and resume normal
(quiet) monitoring.
Ì To transmit, monitor the channel
and make sure it is clear.
THIS IS AN FCC REQUIRMENT!
Ì To transmit, press and hold in the
PTT switch. Speak into the mi-
crophone area of the front panel
grille (lower left-hand corner) in
a normal voice level. To return to
the Receive mode, release the PTT switch.
Ì If a Speaker/Microphone is available, remove the plastic cap
and its two mounting screws from the right side of the trans-
ceiver, then insert the plug from the Speaker/Microphone into
the MIC/SP jack; secure the plug using the screws supplied
with the Speaker/Microphone. Hold the speaker grille up next
to your ear while receiving. To transmit, press the PTT switch
on the Speaker/Microphone, just as you would on the main
transceiver's body.
Note:Save the original plastic cap and its mounting screws.
They should be re-installed when not using the Speaker/
Microphone.
Accessories & Options
FNB-64
7.2 V 700 mAh Ni-Cd Battery
FNB-V57
7.2 V 1100 mAh Ni-Cd Battery
FNB-V57IS Intrinsically-Safe 7.2 V 1100 mAh Ni-Cd Battery
FNB-V67LI 7.4 V 1600 mAh Lithium-Ion Battery
FBA-25
Alkaline Battery Case
NC-77C
220-240 VAC Overnight Desktop Charger
NC-77U
230 VAC Overnight Desktop Charger
VAC-800
Desktop Rapid Charger (for FNB-64/-V57/-V57IS)
VAC-810
Desktop Rapid Charger (for FNB-V67LI)
VAC-6800
6-unit Multi Charger
MH-45
Speaker/Microphone
B4B
MH-37
Earpiece Microphone
A4B
VC-25
VOX Headset
VCM-1
Mobile Mounting Bracket (for VAC-800/-810)
CT-42
PC Programming Cable
CT-27
Radio to Radio Programming Cable
CE64
Programming Software
VTP-50
VX-Trunk Unit
FVP-25
Encryption/DTMF pager Unit
FVP-35
Encryption Unit (Rolling code voice scrambler)
DVS-5
Voice Storage Unit
MDC1200
Digital ANI encoder Unit
This device complies with Part 15 of the FCC rules. Op-
eration is subject to the condition that this device does
not cause harmful interference.

Advertisement

loading

Summary of Contents for Vertex Standard VX-410 Series

  • Page 1 “Click.” be connected until you are familiar with the basic operation Glows Green Monitor on (or Side 1, 2 switch is activated : VX-410 series only) of the VX-410/-420. Blinking Green Busy Channel (or SQL off) Ì To transmit, monitor the channel...
  • Page 2 Soft keys functions can be customized (set to other functions), systems (separate receive and transmit frequencies, utilizing a For further details, contact your VERTEX STANDARD dealer. via programming by your VERTEX STANDARD dealer, to meet Squelch Off “repeater” station). The Talk Around feature allows you to by- your communications/network requirements.

This manual is also suitable for:

Vx-420 series