4.2 Parameter adjustment procedure for brake
sequence function
Set f460 and f462 following to the table mentioned in 4.3 prior to use brake sequence function,
Set related parameters such as cmod, fmod.
Set vector control parameters (motor constant value) by executing the
auto-tuning functions without load.
Execute the brake timing learning function without load to roughly
adjust the brake ON/OFF timing.
If brake is not active at switching forward/ reverse operation, adjust
speed reference filter coefficient (f462).
Operate lifting (forward)/lowering (reverse) run with maximum load, and
confirm that there is no trouble like 'inverter trip' or 'luggage shifts'.
If 'inverter trip' or 'luggage shifts' occurs, adjust parameters for brake
sequence function.
Completion
15