14. White Balance, Luminance Adjustment

1. Equipment and program: analyzer CA210, PC, tool, FGA adjustment program (PHILIPS160EL1.DDCI), pattern
generator.
2. Equipment installation:
a. Connect analyzer CA210 to PC by USB connector, install drive program CA-SDK Ver4.00 for CA210 and restart
PC after finish installing
b. Install Port95NT drive program, set PC printer connector mode as ECP mode and reset PC after finish installing.
c. Connect tool as follow:
Note: It's not necessary to connect Port2.
3. Adjustment
Preparation before adjustment:
a. Monitor should be warmed up for more than half an hour.
b. Make sure that the tools are connected right and drive programs have been installed OK.
Adjustment process:
a. Press the power of CA210, shut off the lens, press 0-CAL and open the lens after analyzer reset.
b. Open white balance adjustment program, select the right parameter according with the program and click OK.
c. Make sure that the lens of CA210 aims at the center of the screen, then click START to adjust.
d. After finish adjusting, the adjustment program displays pass, and the START button changes for NEXT, which
means that you can adjust another monitor.
To PC Port 2
To CA210 or
equivalent instrument
To PC LPT
Meridian 1
Philips 160EL1