Combustible Mantels - Regency U31 Specification Sheet

Gas inserts

Advertisement

Clearances
Unless otherwise stated the clearances listed below are Minimum
distances to combustible materials. Please Note: A major cause
of chimney related fi res is due to a failure to maintain required
clearances (air space) to combustible materials. It is of the greatest
importance that this fi replace and vent system be installed only in
accordance with these instructions.
F
C
A
D
Clearances to Combustibles
Dimension
Description
A
From Unit to Sides
B
From Unit to Ceiling
C
From Unit to Mantel
D
From Standard Surround to Sides
E
From Standard Surround to Ceiling
F
Minimum Mantel Height
G
Maximum Mantel Depth
H
Minimum Alcove Width
I
Maximum Alcove Depth
*No Hearth Required
Clearances when installed with a Zero Clearance Kit
Dimension
Description
F
Minimum Mantel Height
G
Maximum Mantel Depth
120
B
E
G
I
H
U31
10" (254mm)
47-1/2" (1207mm)
see mantel clearances
4" (102mm)
41-1/2" (1054mm)
13" (330mm)
12" (305mm)
48" (1219mm)
36" (914mm)
U31
20" (508mm)
11-1/2" (292mm)
Gas Inserts

Combustible Mantels

Because of the extreme heat this fi replace emits, the mantel
clearances are critical. Combustible mantel clearances from top of
the louvers are shown in the diagram below. Mantel may be installed
anywhere in the shaded area or higher.
NOTE: Mantel clearances for Installation into a Zero Clearance Kit
are different. Please refer to the Zero Clearance Kit Manual
for details.
Note: A non-combustible mantel may be installed at a lower
height.
Note: Ensure the paint that is used on the mantel and the facing
is "heat resistant" or the paint may discolour.
August 2008 Product Specifi cations Book
U31 Regency Gas Insert