Download Print this page

UTICA BOILERS TS-100 Instruction Manual page 2

Ts series & tt series torque limiting screwdrivers

Advertisement

45-8447
Recalibration of the Utica Adjustable Torque Screwdrivers
Adjust to the min.
torque output.
TS-30 = 6 in-lb
TS-35 = 6 in-lb
TS-3M = 5 cm-kg
TS-100 = 20 in-oz
TT-1 = 2 in-oz
Turn adjusting knob to
equal setting of measured
torque output.
Torque output should
equal the reading on
the tester within ±4%.
Torque Limiting Screwdrivers
Proper calibration equipment is required to ensure accuracy!
If calibration is not
correct, adjust the
screwdriver to achieve
an output equal to that
shown in step 1.
1
4
7
Recheck the setting
shown in setp 2.
10
Utica
®
2
5
Turn clockwise
to increase
and counter-
clockwise to
decrease the
maximum
torque setting.
8
11
Adjust to the max.
torque output.
TS-30 = 30 in-lb
TS-35 = 35 in-lb
TS-3M = 30 cm-kg
TS-100 = 100 in-oz
TT-1 = 20 in-oz
Recheck the
screwdriver with the
maximum setting.
3
6
9

Advertisement

loading

This manual is also suitable for:

Ts-30Ts-3mTs-35Ts-sn-1Tt-1Ts-sn-2 ... Show all