Heating Speed Charts - Amana GUIA070A30 Service Instructions Manual

40" 80% gas furnaces guia, gcia, guib, gcib, guic, gcic, guid, guis, gcis, guiv & accessories
Table of Contents

Advertisement

BLOWER PERFORMANCE SPECIFICATIONS
("W1" must be connected to "W1" on Two-Stage Integrated Furnace Control)
("W2" must be connected to "W2" on Two-Stage Integrated Furnace Control)
GUIV070DX40
CFM @
Heating
.1 to .5 "WC
Adjust
Low Stage
Speed
Low Stage
ESP
A
Minus
585
A
Normal
650
A
Plus
715
B
Minus
630
B
Normal
700
B
Plus
770
C
Minus
720
C
Normal
800
C
Plus
880
D
Minus
810
D
Normal
900
D
Plus
990
GUIV115DX50
CFM @
Heating
.1 to .5 "WC
Adjust
Low Stage
Speed
Low Stage
ESP
A
Minus
945
A
Normal
1050
A
Plus
1155
B
Minus
990
B
Normal
1100
B
Plus
1210
C
Minus
1080
C
Normal
1200
C
Plus
1320
D
Minus
1170
D
Normal
1300
D
Plus
1430
1. Units are shipped without filter(s). CFM in chart is without filter(s).
2. All furnaces shipped with heating speed set at "B" and cooling speed set at "A". Installer should adjust blower speeds
as needed.
3. INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE
RATING PLATE.
4. The chart is for information only. For satisfactory operation, external static pressure not to exceed value shown on
rating plate.
5. The above chart is for U.S. furnaces installed at 0-2000 feet. At higher altitudes, a properly derated unit will have
approximately the same temperature rise at a particular CFM, while the ESP at that CFM will be lower.
TWO STAGE - VARIABLE SPEED

Heating Speed Charts

CFM @
.1
Rise
Rise
to .5 "WC
High Stage
High Stage
High Stage
Natual
Propane
(°F)
ESP
(°F)
61
55
936
55
50
1030
50
56
907
56
51
1008
51
46
1109
46
49
1037
49
44
1152
44
40
1267
40
44
1166
44
40
1296
39
36
1426
36
CFM @
.1
Rise
Rise
to .5 "WC
High Stage
High Stage
High Stage
Natual
Propane
(°F)
ESP
(°F)
63
1361
63
56
1512
56
51
1663
51
60
1426
60
54
1584
54
39
1742
49
55
1555
55
49
1728
49
45
1901
45
51
1685
51
46
1872
46
41
2059
41
Rise
CFM @
Heating
.1 to .5 "WC
Adjust
Speed
Low Stage
(°F)
ESP
55
A
Minus
801
49
A
Normal
890
45
A
Plus
979
51
B
Minus
588
46
B
Normal
950
41
B
Plus
1045
44
C
Minus
945
40
C
Normal
1050
36
C
Plus
1155
39
D
Minus
1049
35
D
Normal
1165
32
D
Plus
1282
Rise
CFM @
Heating
.1 to .5 "WC
Adjust
Speed
Low Stage
(°F)
ESP
56
A
Minus
945
51
A
Normal
1050
46
A
Plus
1155
54
B
Minus
990
48
B
Normal
1100
44
B
Plus
1210
49
C
Minus
1080
44
C
Normal
1200
40
C
Plus
1320
46
D
Minus
1170
41
D
Normal
1300
37
D
Plus
1430
GUIV090DX50
CFM @
.1
Rise
Rise
to .5 "WC
High Stage
Low Stage
High Stage
Natual
(°F)
ESP
(°F)
59
1153
59
53
1282
53
48
1410
48
55
1231
55
50
1368
50
45
1505
45
50
1361
50
45
1512
45
41
1663
41
45
1510
45
41
1678
41
37
1845
37
GUIV140DX50
CFM @
.1
Rise
Rise
to .5 "WC
High Stage
Low Stage
High Stage
Natual
(°F)
ESP
(°F)
75
1361
75
68
1512
68
62
1663
61
72
1426
72
65
1584
65
59
1742
59
66
1555
66
59
1728
59
54
1901
54
61
1685
61
55
1872
55
50
2059
50
33
Rise
High Stage
Propane
(°F)
53
48
44
50
45
41
45
41
37
41
37
33
Rise
High Stage
Propane
(°F)
68
61
55
65
58
53
59
53
48
55
49
45
Rev. 2