Operator Manual Water Boilers ME10EN, ME15EN Model ME15EN Model ME10EN Table of Contents Safety Information....2 Adjustments ......6 Rough-In Drawing....3 Maintenance ......7 Installation.......4 Parts Diagram......9 Priming ........5 Wiring Diagram.....10 Cleaning........5 Thank you for purchasing this quality boiler. For your safety and the safety of others, read all warnings and the operator manual before installing or using the product.
This equipment must be installed in compliance with applicable Federal, State and/or Local plumbing codes having jurisdiction. This product requires an approved backflow prevention water device, such as a double check valve, that must be installed between the machine and the water supply. GB Series Cecilware Cecilware Water Boilers ®...
7,900 10 AWG NOTE: 1. FIELD WIRING MUST BE SUITABLE FOR 75 DEGREES CELSIUS. 2. USE COPPER WIRE ONLY FOR POWER SUPPLY CONNECTION. 3. 120 VOLT UNITS SUPPLIED WITH A GROUNDED 120V-15A LINE CORD AND PLUG. Water Boilers Cecilware ®...
It was thoroughly inspected before leaving machine and the water supply. Incoming pressure should the factory. In case of damage, contact the shipper, not be greater than 30 psi and not more than 70 psi. Grindmaster-Cecilware. NOTICE: NOTICE: The person installing this appliance is...
Switch OFF the power to the unit at the circuit breaker. Turn off the water line running to the boiler. 1. With power to the unit disconnected, fill unit to capacity. 2. Prepare a sanitizing solution in accordance with Water Boilers Cecilware ®...
The Heater Light will go ON, indicating the heating element is activated, wait for it to go OFF, indicating that the water has reached new set temperature. 4. Take a temperature reading and repeat if necessary. Cecilware Water Boilers ®...
Prior authorization must obtained from electrical wiring. Grindmaster-Cecilware for all warranty claims. 4. Check dual probe liquid level controller. (See Grindmaster-Cecilware provides the industry’s Component Tests) BEST warranty. Visit our website at gmcw.com for warranty terms and conditions. If Water Runs Out At Overflow Drain 1.
Page 8
3. Make sure all wire connections are tight, including ground. 4. If after this, the Controller is still failing to open the Water Inlet Valve, replace it. If lack of water persists, check the probe as follows: Cecilware Water Boilers ®...