Post-Replacement Procedures; Start Up The Storage System And Expansion Enclosure; Send Diagnostic Data Using Dell Supportassist; Change The Operation Mode Of The Storage Center To Normal - Dell SCv360 Owner's Manual

Expansion enclosure
Hide thumbs Also See for SCv360:
Table of Contents

Advertisement

Next steps
1.
Power on the expansion enclosure and storage system.
2.

Change the operation mode of the Storage Center to Normal.

3.
Use SupportAssist to send diagnostic data to Dell Technical Support.

Post-Replacement Procedures

After replacing a component in the SCv360 expansion enclosure, start up the SCv3000 series storage systems and the SCv360
expansion enclosures if they were previously shut down, then use SupportAssist to send diagnostic data to Dell Technical Support.

Start Up the Storage System and Expansion Enclosure

If the storage system and expansion enclosure were previously shut down, perform this procedure to start them up.
1.
Power on the expansion enclosure by plugging the power cables into the PSUs.
NOTE: Wait approximately three minutes for the drives in the expansion enclosure to spin up before powering on the
storage system.
2.
Plug the power cables into the power supply/cooling fan modules of the storage system.
3.
Power on the storage system by pressing the power switches on both power supply/cooling fan modules to the ON position.
4.
Use the Dell Storage Manager to make sure the replacement part is recognized and shown as up and running.

Send Diagnostic Data Using Dell SupportAssist

After replacing components, use Dell SupportAssist to send diagnostic data to Dell Technical Support.
1.
Use Dell Storage Manager to connect to the Storage Center.
2.
In the Summary tab, click Send SupportAssist Information Now, which is located under SupportAssist Actions in the Status
pane.
The Send SupportAssist Information Now dialog box opens.
3.
Select Storage Center Configuration and Detailed Logs.
4.
Click OK.
Change the Operation Mode of the Storage Center to Normal
Change the operation mode of the Storage Center to Normal after replacing components.
1.
Use Dell Storage Manager to connect to the Storage Center.
2.
In the Summary tab, click Edit Settings. The Edit Storage Center Settings dialog box opens.
3.
Click the General tab.
4.
In the Operation Mode field select Normal.
5.
Click OK.
Replacing SCv360 Expansion Enclosure Components
63