Advertisement

Criteria
5. HDMI Test
Procedure
Inspection item
Criteria

4-9 Optical Performance Measure

Inspection Condition
- Environment luminance: 2 Lux
- Product must be warmed up for 3 minutes
- Distance from the screen: 2 M
- Screen Size: 60 inches diagonal
1. Test equipment
Procedure
2. Brightness
Procedure
- Check the sound from speaker.
- Check if "Volume" is normal
- Check if "Mute" is normal
- Test Signal : 720p,1080i
- Test Pattern : Any Pattern
- Equipment: DVD Player with HDMI output
- Display type must be set to 16:�
- HDMI Test
- Ensure the image and audio are well performed
and the color can not discolor.
- Connect VGA IN port of Projector with VGA port
of Chroma by VGA cable, press "Menu" button,
get into OSD mode, the settings are as below:
- "Display mode" is "Bright", "Brightness" is "50",
the "Format" is "16:�", and "ECO Mode" is "Off".
- Full white pattern
- Use CL100 to measure brightness values of
Full white pattern
H6500