Resolvers - Siemens MASTERDRIVES MC 1FK7 Configuration Manual

Synchronous motors
Table of Contents

Advertisement

Motor Components (Options)
Encoders
4.2.4

Resolvers

Notice
The max. operating frequency of 432 Hz must be observed with SIMODRIVE 611
universal HR.
(encoder frequency = motor speed x pole pair number of the resolver /60)
Function:
Table 4-9:
Features
Excitation voltage
Excitation frequency
Current consumption
Angular accuracy (bandwidth)
2-pole
multi-pole
Pole number
(the pole number is the same as
the motor pole number)
Ratio
Fig. 4-4
4-8
Speed actual value sensing
Rotor position encoder for inverter control
Indirect incremental measuring system for the position control loop
Technical data, resolvers
Output signals, resolver
1FK702
- 1FK703
5 V (rms) up to 13 V (rms)
4 kHz to 10 kHz
< 80 mA (rms)
< 20'
< 7'
2, 6
0.5
Configuration Manual (PFK7), 10/2005 Edition, 6SN1197-0AD06-0BP1
1FK704 -10
5 V (rms) up to 13 V (rms)
4 kHz to 10 kHz
< 80 mA (rms)
< 14'
< 4'
2, 4, 6 or 8
0.5
1FK7 Synchronous Motors