Figure 2-1 Dla Forward Direction Interconnect Diagram; Table 2-1 - Forward Direction Rf Port Functions - Andrew 2400 Operation And Maintenance Manual

Distribution line amplifier
Table of Contents

Advertisement

385700-4006-006
FORWARD CONFIGURATION : DIRECTION CONTROL = NORMAL
USER Control
Equipment
®
HELIAX
NORM PA IN
BDR 1
®
RADIAX
VAC Power
RF Port
J3 – LNA In
J3 – Norm PA Out1
J4 – Norm PA In
J4 – LNA Out
J5 – Norm PA Out2
J6 – Norm Det In
DLA
ALARM/CONTROL
NORM PA
J2
OUT2
NORM PA OUT1
LNA IN
LNA OUT
J3
J4
POWER IN
NORM DET IN
J1
J6
BDR 1
ZONE

Figure 2-1 DLA Forward Direction Interconnect Diagram

Frequency
2467.84 MHz ± 13.5 MHz
2416.64 MHz ± 13.5 MHz
2416.64 MHz ± 13.5 MHz
2467.84 MHz ± 13.5 MHz
2416.64 MHz ± 13.5 MHz
2416.64 MHz ± 13.5 MHz
Table 2-1 – Forward Direction RF Port Functions
Document use is restricted to that described on cover
®
RADIAX
J5
®
HELIAX
®
RADIAX
®
RADIAX
Input/Output
INSTALLATION
DLA
ALARM/CONTROL
NORM PA
J2
NORM PA OUT1
NORM PA IN
LNA IN
LNA OUT
J3
J4
POWER IN
NORM DET IN
J1
J6
4 Port/2 Port
I
O
I
O
0
4 Port only
I
4 Port only
®
RADIAX
OUT2
®
J5
HELIAX
BDR 2
®
RADIAX
BDR 2
ZONE
Y
Y
Y
Y
2-3

Advertisement

Table of Contents
loading

Table of Contents