Ordering - GE L60 Instruction Manual

Line phase comparison system ur series
Hide thumbs Also See for L60:
Table of Contents

Advertisement

2.1 INTRODUCTION
Table 2–2: OTHER DEVICE FUNCTIONS
FUNCTION
Breaker Arcing Current (I
Breaker Control
Breaker Flashover
2
Contact Inputs (up to 96)
Contact Outputs (up to 64)
Control Pushbuttons
CT Failure Detector
CyberSentry™ security
Data Logger
Digital Counters (8)
Digital Elements (48)
Direct Inputs and Outputs (32)
Disconnect Switches
DNP 3.0 or IEC 60870-5-104 Communications
Event Recorder
Fault Location
Fault Reporting
FlexElements™ (8)
FlexLogic Equations
IEC 61850 Communications (optional)
Line Pickup
Load Encroachment
The L60 is available as a 19-inch rack horizontal mount unit or a reduced size (¾) vertical mount unit, and consists of the
following modules: CPU, faceplate, power supply, CPU, CTs and VTs, digital input and outputs, transducer inputs and out-
puts, and inter-relay communications. Each of these modules can be supplied in a number of configurations specified at the
time of ordering. The information required to completely specify the relay is provided in the following tables (see chapter 3
for additional details of relay modules).
The L60 is specified with two CT/VT modules (8F and 8P). When the L60 is applied in two-breaker configurations (such as
breaker-and-a-half or ring configurations), the currents from the two CTs are summed internally within the relay or exter-
nally. If the voltage is not supplies to the relay, some functions (such as distance, undervoltage, and synchrocheck) will not
be available.
Order codes are subject to change without notice. See the GE Multilin ordering page at
http://www.gedigitalenergy.com/multilin/order.htm
NOTE
The order codes for the horizontal mount units are shown below.
Table 2–3: L60 ORDER CODES (HORIZONTAL UNITS)
L60
-
*
**
- *
BASE UNIT
L60
|
|
CPU
T
|
U
|
V
|
2-4
FUNCTION
2
t)
Metering: Current, Voltage, Power, Frequency
Modbus Communications
Modbus User Map
Non-Volatile Latches
Non-Volatile Selector Switch
Open Breaker Echo
Open Pole Detector
Oscillography
Pilot Scheme (POTT)
Setting Groups (6)
Time synchronization over IRIG-B or IEEE 1588
Time Synchronization over SNTP
Transducer Inputs/Outputs
Trip Bus
User Definable Display
User Programmable LEDs
User Programmable Pushbuttons
User Programmable Self-Tests
Virtual Inputs (64)
Virtual Outputs (96)
VT Fuse Failure
*
* - F
**
- H
**
- L
**
- N
**
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
L60 Line Phase Comparison System
for the latest ordering options.
- S
**
- U
**
- W/X
**
For Full Sized Horizontal Mount
|
|
|
|
Base Unit
|
|
|
|
RS485 and Three Multi-mode fiber 100Base-FX (SFP with LC)
|
|
|
|
RS485 with 1 100Base-T Ethernet, SFP RJ-45 + 2 100Base-FX Ethernet, multimode, SFP with LC
|
|
|
|
RS485 with 3 100Base-T Ethernet, SFP with RJ-45
2 PRODUCT DESCRIPTION

2.1.2 ORDERING

GE Multilin

Advertisement