Total Frames
6.7.2.2
Indicates number of valid Ethernet frames in the Ethernet XMT/radio RCV data.
Error Frames
6.7.2.3
Frame Check Sequence (FCS) error count indicates the number of Ethernet frames
with errors in the Ethernet XMT/radio RCV data.
Dropped Frames
6.7.2.4
Indicates number of Ethernet frames dropped due to errors in the Ethernet XMT/radio
RCV data, or lack of buffer space.
DS1/E1 RADIO CONTROL SCREEN
6.8
See Figure 6 - 10. The Control screen is used to enable or disable and display the status
of manual controls. Manual controls include equipment and function in-service con-
trols, system loopback controls, user controls, and DS1/E1 loopback controls. The green
square indicates control is enabled. Highlight and click on control name to change
state.
In-Service Controls
6.8.1
IN-SERVICE controls are used to force A or B transmitter, receiver, and I/O interface
modules on -or off-line. IN-SERVICE manual controls are also used to lock the A or B
transmitter ATPC function high ( ATPC High Pwr Lock) or low ( ATPC Low Pwr Lock).
System Loopback Controls
6.8.2
When enabled, SYSTEM LOOPBACK manual controls loop I/O receiver to I/O trans-
mitter (I/O LOOPBACK). I/O LOOPBACK is a local loopback function that can be used
to test the performance of a standalone radio.
User Controls
6.8.3
USER CONTROLS , defined by the customer and named on the User Control Names
Setup screen, are displayed and can be enabled or disabled if the optional AE -37( )
Relay Interface module is installed.
DS1 Line Loopback Controls
6.8.4
See Figure 6 - 11. When enabled, DS1 LINE LOOPBACK RCV to XMT manual controls
loop DS1/E1 lines individually (Line 1-16 loopback). DS1 LINE LOOPBACK RCV to
XMT is a far-end loopback function that can be used to test over-the-hop.
6 - 11