Siemens SINUMERIK 840DE User Manual page 80

Configuring the ncu sinumerik 840d series
Hide thumbs Also See for SINUMERIK 840DE:
Table of Contents

Advertisement

7 DMP Compact Modules
7.1 DMP compact module 16E 6FC5111-0CA01-0AA0
S
Interfaces
S
S
S
Display elements
16 LEDs as a status display for the logical states of the inputs.
LEDs lit:
Table 7-2
Number of inputs
Galvanic isolation
Power supply V
Input voltage
Input current for signal "1"
Delay time
Delay time
Length for cables
Weight
7-78
A 30-pole connector X1 for connection to the NCU terminal block.
Two 10-terminal X2 and X3 (Phoenix, Type MC1.5/10-ST-3.81 GREY, Order
No. for X3 and X2: 18 28 171) for connecting the 16 inputs and the load
power supply.
The terminals are pluggable and can be mechanically coded by the custo-
mer.
The 24 V terminal P (24 V) is not used
Input on.
Technical data DMP compact module 16 I
LOAD
– Rated value
– Perm. range
– Ripple
– Rated value
– For signal "0"
– For signal "1"
for tp
for tp
SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition
16 digital inputs
Yes
24 V DC
20.4 V to 28.8 V
3.6 Vpp
24 V DC
–3 to +5 V
+13 V to +33 V
+2 mA to +5 mA
tp
= type 1 ms
LH
LH
tp
= type 1 ms
HL
HL
Maximum 30 m
About 125 g
© Siemens AG, 2006. All rights reserved