ADJUSTING THE BREWER
The CBS-2121-Automatic uses easy & intuitive touch screens to access and adjust brewer internal settings.
Brew start, heaters, fill and hot water valve are disabled in PROGRAMMING mode
TO ENTER PROGRAMMING
INPUT
BOX
↑
POWER SWITCH
-TURN POWER SWITCH TO "OFF"
-TURN POWER SWITCH "ON"
-The OPENING SCREEN will display
+
READI
IINPUT
‐
START
exit
TEMP.
MODE Automatic
IMMEDIATELY—
Touch & Hold the INPUT BOX on the
touch screen
+
NEXT
‐
.
exit
Uni
ts
TEMP.
SECOND SCREEN
Tank temperature units.
Touch the + or – box to toggle from
degrees Celsius or Fahrenheit
Press NEXT to go to third
programming screen-OR-press exit
to save settings & leave
Go to fetco.com for the latest versions of all information
VOLUME TEMPERATURE AND UNITS
+
‐
exit
FIRST SCREEN
Manual/Automatic fill mode
AUTOMATIC FILL MODE
-the brewer is attached to water
supply for self-fill and brew.
Brews are timed and selectable for
full or half batch.
The (default) 360 second START
timer is set for 2:70 mm:ss brew
and 90 second drip out
MANUAL FILL MODE
BOX
Water inlet valve disabled.
Do not press "START" Icon" if
brewer is in MANUAL Mode
This is to use the optional
Pourover-manually operated
--
-Press NEXT to go to second
programming screen-OR-press exit
to save settings & leave
+
‐
.
exit
°F
THIRD SCREEN
Set hot water tank temperature.
Touch the + or – box to raise or lower
tank temperature
-Default is 95°C
-Range is 82-97°C
Press NEXT to go to fourth
programming screen-OR-press exit to
save settings & leave
NEXT
.
MODE AUTOMATIC
feature
NEXT
200°F
TEMP.
Page 6
+
NEXT
‐
exit
Automatic
MODE
‐
+
NEXT
‐
exit
Manual
MODE
Pressing the middle [-] tab toggles the
brewer to MANUAL (pour-in) mode.
Touch top-left [+] tab to return controls
to AUTOMATIC mode
+
NEXT
exit
L
FOURTH SCREEN
Set Full Batch (Batch #1) Volume.
Touch the + or – box to set
FULL BATCH volume
Default is 1.8 liter.
Volume range is 0.5 to 2.5 liters
Press NEXT to go to fifth programming
screen-OR-press exit to save settings &
leave
P169 MARCH 2018
1.8