Item
Player mode and button
combination
Version display
In STOP (no disc) or
PLAY mode, press
PLAY and
OPEN/CLOSE buttons
on the player, and "7"
button on the remote
control unit. (Press "FL
SELECT" key on the
remote control unit to
change the FL display
for Display1 or
Display2.)
Lighting of display
In any mode, press
tube
PLAY and
OPEN/CLOSE buttons
on the player, and "9"
button on the remote
control unit.
Dealer´s lock
In PLAY mode, press
ON/OFF shift
PLAY and
function
OPEN/CLOSE buttons
on the player, and
QUICK REPLAY button
on the remote control
unit.
Initialization
In STOP (no disc)
mode, press PLAY,
OPEN/CLOSE and
POWER buttons on the
payer for 3 seconds or
longer.
All reset
When initialization by
the user is performed
and "INITIALIZATION"
is displayed, press
PLAY and
OPEN/CLOSE buttons
on the player.
Region display
In STOP (no disc) or
PLAY mode, press
PLAY and
OPEN/CLOSE buttons
on the player, and "6"
button on the remote
control unit.
Timer 1 check
In STOP (no disc)
mode, press PLAY and
OPEN/CLOSE buttons
on the player, and "1"
button on the remote
control unit. (Press "FL
SELECT" key on the
remote control unit to
change the FL display
for Display1 or
Display2.)
Timer 1 reset
While displaying Timer
1 data, press PLAY and
OPEN/CLOSE buttons
on the player, and "2"
button on the remote
control unit. (Press "FL
SELECT" key on the
remote control unit to
change the FL display
for Display1 or
Display2.)
Function
Version display
Lighting of display tube
Dealer´s lock ON/OFF shift function
The lock is switched ON or OFF.
When dealer´s lock is on, it prohibits
switching off of the secondary power
and tray opening. When the lock is
switched, its ON/OFF status is stored
in FLASHROM.
Initialization
User settings are cancelled and
player is initialized to factory setting.
Initialization
User settings are cancelled and
player is initialized to factory setting.
The setting resistance reference
value and unit information spreaded
globally of the OP_CON unit are
stored in FLASHROM.
Note: the operation timer of the laser
and spindle motor is not initialized.
Region display and unit setting
Timer 1 check
Laser operation timer is measured
separately for DVD laser and CD
laser.
Timer 1 reset
Laser operation timer is reset.
25
DVD-S2EE / DVD-S2GC / DVD-S2GCA / DVD-S2GCS / DVD-S2GCU / DVD-S2PL / DVD-S2PLA
FL Display
In case of no OP_CON unit, only the system
controlled software version number is
displayed.
Lighting of all display tube
"LOC" sign appears when dealer´s lock is
switched on, or when POWER button or
OPEN/CLOSE button is pressed while the lock
is on.
"UNLOC" sign appears when dealer´s lock is
switched off.
INI
RESET
T1_1234_5678 (display1/display2)
Shown to the left is DVD laser time and to the
right CD laser time.
Time is shown in 4 digits of decimal notation in
a unit of 10 hours.
"0000" will follow "9999".
T1_0000_0000 (display1/display2)
Cancellation
method
Cancelled
automatically 5
seconds later.
Repeat the same
operation.
Repeat the same
operation.
Cancelled
automatically 5
seconds later.
Cancelled
automatically 5
seconds later.
Cancelled
automatically 5
seconds later.

Advertisement

Table of Contents
loading

Table of Contents