Embedded Window Frame Security Sensor
Installation Instructions
The Embedded Window Frame Sensor/Transmitter
transmits a wireless security message to the System Control Panel. This is accomplished through the use
of a sensor unit (which contains the wireless transmitter and battery), and magnet unit. When the two are
separated, by opening the window, the sensor transmits an OPEN signal to the System Control Panel.
When the window is shut, the magnet is again within the sensor's range, and a CLOSE signal is sent.
Fig 1: Sensor and Magnet
The sensor sends supervisory signals to the panel every 64 minutes (approximately). The sensor is
powered by a 3.0V, lithium battery, model CR1632. The sensor has been designed to draw little power,
and provide long battery life. The entire package needs to be removed from the window frame for the
battery to be replaced.
Required Tools for Installation
Electric Drill
SDI Custom Frame Drill Bit
Pencil or chalk
Installation Sheet for documenting sensor locations
Guidelines
The following guidelines will help ensure that installations are safe and efficient.
A sensor can be mounted on any side of the window frame (top, side, or bottom), such that the opening
of the window moves the magnet away from the sensor.
Always try to mount the hardware such that the magnet, not the sensor, is in the moving window panel.
The sensor can be installed in the moving window panel, but should be avoided.
Do not install the sensor in the frame until after the Electronic Serial Number (ESN) has been entered
into the panel, and the wireless sensor confirmed within range. The 6 digit (including HEX values)
ESN is labeled on the device.
Sensor's should be kept as close to the panel or repeater as possible. Try to chose locations where the
separation is within 100 ft.
Avoid mounting the sensor in a location where it will be exposed to moisture.
Avoid mounting a sensor where temperatures are excessively hot or cold.
This device cannot be mounted in a metal frame, as the frame will block the antenna (there is an
external version of this device that will fit on the exterior of an aluminum frame).
WARNING:
Some installations may have electrical wiring running through the door or window
frames. Use caution to avoid electrical shocks.
ION Digital LLP
P.O. Box 3969 Blaine Washington
USA 98231
detects when a window is closed or opened, and
Magnet
Sensor & Antenna
1 of 6
Installation Guide
11/04/02
Ph#
1-800-407-4389
Fax# 1-800-407-4465
www.ion-digital.com

Advertisement

loading

Summary of Contents for ION QN3WD01

  • Page 1 FCC ID: QN3WD01 Installation Guide ION Digital LLP 11/04/02 Embedded Window Frame Security Sensor Installation Instructions The Embedded Window Frame Sensor/Transmitter detects when a window is closed or opened, and transmits a wireless security message to the System Control Panel. This is accomplished through the use of a sensor unit (which contains the wireless transmitter and battery), and magnet unit.
  • Page 2: Fig 2. Correct Positioning The Magnet And The Sensor Relative To Each Other

    FCC ID: QN3WD01 Installation Guide ION Digital LLP 11/04/02 Preparation Determine a suitable location for the sensor and the magnet. These units are meant to be mounted inside the frame of the window. As such do not drill a mounting hole unless: •...
  • Page 3 FCC ID: QN3WD01 Installation Guide ION Digital LLP 11/04/02 Fig 3: Incorrect Orientation of Magnet and Sensor Direction of Window Movement, magnet moves over and past sensor. 3 of 6 ION Digital LLP 1-800-407-4389 P.O. Box 3969 Blaine Washington Fax# 1-800-407-4465 USA 98231 www.ion-digital.com...
  • Page 4 FCC ID: QN3WD01 Installation Guide ION Digital LLP 11/04/02 Entering and Testing Sensors The sensors need to be entered into the control panel memory. This is done by entering the 6 digit (including HEX values) ESN into the panel to record it. Refer to your panel installation manual for complete details.
  • Page 5: Installation In Window Frame

    IMPORTANT !!! Ensure the Sensor is lined up in the window frame such that the ION Logo is pointing out the window. This is required to line the magnet and the sensing device properly.
  • Page 6: Fcc Notice

    CAUSE HARMFUL INTERFERNCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. Changes or modifications not expressly approved by ION Digital LLP can void the user’s authority to operate the equipment. 6 of 6...