Kenwood TH-D72A Service Manual page 48

144/440 (430) mhz fm dual bander
Hide thumbs Also See for TH-D72A:
Table of Contents

Advertisement

TH-D72A/D72E
Item
Condition
4. Power
4) Power: LOW
Check [7.4V]
Frequency: 144.100MHz
Battery
Transmission
5) Power: LOW
Frequency: 147.900MHz K
Transmission
6) Power: EL
Frequency: 144.100MHz
Transmission
7) Power: EL
Frequency: 147.900MHz K
Transmission
8) Power: HI
Frequency: 444.100MHz K
Transmission
9) Power: HI
Frequency: 438.100MHz K
Transmission
10) Power: HI
Frequency: 444.900MHz K
Transmission
11) Power: LOW
Frequency: 438.100MHz K
Transmission
12) Power: LOW
Frequency: 444.900MHz K
Transmission
13) Power: EL
Frequency: 438.100MHz K
Transmission
14) Power: EL
Frequency: 444.900MHz K
Transmission
5. Power
DC-IN: 13.8V
Check
1) Power: HI
[13.8V]
Frequency: 146.100MHz K
DC-IN
Transmission
2) Power: HI
Frequency: 144.100MHz
Transmission
3) Power: HI
Frequency: 147.900MHz K
Transmission
48
ADJUSTMENT
Measurement
Test-
equipment
Power
meter
Ammeter
145.900MHz E
145.900MHz E
435.100MHz E
430.100MHz E
439.900MHz E
430.100MHz E
439.900MHz E
430.100MHz E
439.900MHz E
Power
meter
Ammeter
145.100MHz E
145.900MHz E
Adjustment
Unit
Terminal
Unit
Parts
ANT
ANT
Specifi cations / Remarks
Method
Check
0.2W~0.8W
0.9A or less
10mW or more
0.6A or less
4.5W~5.1W
2.2A or less
0.2W~0.8W
0.9A or less
10mW or more
0.6A or less
Check
4.5W~5.5W
1.8A or less

Hide quick links: