LG TCD1870QGS Service Manual page 44

Hide thumbs Also See for TCD1870QGS:
Table of Contents

Advertisement

A. Conversion information
Gas type
Natural Gas
MFX62442001
Propane Gas MFX62442002
B. Normal operating sequence of the ignition system
① Ignition controller will spark for 10 seconds after ignition
② Ignition controller will stop to spark after ignition
C. Check list to verify the input rate of the converted clothes dryer(See A, D)
① Conversion connector
③ Input and Manifold pressure (See picture 2)
④ Gas type
⑤ Altitude
D. De-rating at altitudes above 2000 ft (610m)
Dryer input ratings are based on measurements of altitude above sea level and need not be adjusted for altitude
levels up to 2000 ft (610m). Input ratings should be reduced at the rate of 4 percent for each 1000 ft (305m) above
sea level.
NOTE : THE CONVERSION SHALL BE CARRIED OUT BY A MANUFACTURER'S AUTHORIZED
REPRESENTATIVE, IN ACCORDANCE WITH THE REQUIREMENTS OF THE MANUFACTURER,
PROVINCIAL OR TERRITORIAL AUTHORITIES HAVING JRISDICTION AND IN ACCORDANCE WITH THE
REQUIREMENTS OF THE CAN/CGA-B149.1 OR CAN/CGA-B149.2 INSTALLATION CODES.
Conversion
Connector Marking
X
O
Picture 1
Input rating
340
55,000BTU/hr
220
55,000BTU/hr
Attach conversion data plate after
44
Inlet gas pressure
Minimum
Maximum
5.0"w.c.
10.5"w.c.
10.0"w.c.
13"w.c.
high altude conversion.
Manifold
Pressure
(max
rating)
3.8"w.c.
8.67"w.c.