Scanning
Scanning Mode
Standby Duration
Same Bar Code Delay Time
16
The trigger button must be pressed to activate scanning.
Good-read off:
The light source of the QS2500 stops scanning when there is a successful
read or no code is decoded after the standby duration has elapsed.
The trigger button acts as a switch. Pressing the button acti-
Momentary:
vates scanning and releasing the button stops scanning.
The trigger button acts as a toggle switch. Pressing the button
Alternate:
activates or stops scanning.
The trigger button must be pressed to activate scanning, and
Timeout off:
the QS2500 stops scanning when no code is decoded after the standby
duration has elapsed.
The QS2500 always keeps reading, and it does not matter
Continue:
whether the trigger button is pressed or the standby duration has elapsed.
Select this mode for use in Stand Mode.
The QS2500 always keeps a constant reading, and same-label
Test only:
reading is allowed without double confirmation. The feature can test the
performance of the QS2500 for reading speed and sensitivity.
A timeout duration of 1 to 99 seconds can be set. It is effective only when
the CCD scanning mode is operated in timeout-off mode and good-read
off mode.
If the bar code has been scanned twice, then only the first bar code will be
accepted.
QS2500