Separator Element Replacement; Minimum Pressure/Check Valve Maintenance - Sullair ES-6 5H Operator's Manual And Spare Parts List

Rotary screw air compressor es--6 series standard & 24kt 5, 7.5 and 10hp 4, 5.5 and 7.5 kw
Hide thumbs Also See for ES-6 5H:
Table of Contents

Advertisement

Figure 6 ---3 Separator Element (P/N 250025 ---264)
* Replacement Element Kit P/N 250028---033
ELEMENT INSPECTION
1. Place a bright light inside the element to inspect
for damage or leak holes. Concentrated light will
shine through the element and locate any holes.
2. Inspect all gaskets and gasket contact surfaces
of the housing. Should faulty gaskets be evident,
correct the condition immediately.
3. If the clean element is to be stored for later use, it
must be stored in a clean container.
4. After the element has been installed, inspect and
tighten (if necessary) all air inlet connections
prior to resuming operation.

SEPARATOR ELEMENT REPLACEMENT

Refer t o
F igur e 6 --
3. F or maintenac e s c hedule, c on-
s u lt
Table 3 -- 1
in
Sec tion
the procedure explained below for element replace-
ment.
!
Before doing compressor maintenance, discon-
nect compressor from power source and lock out
power source. Isolate compressor from line pres-
sure by closing recommended discharge shut- -
off valve and releasing all internal pressure from
compressor.
1. Insert a 4" maximum length, 1/4" diameter pin into
the radially drilled hole in the separator cap.
Loosen, unscrew counterclockwise and remove
the cap.
2. Pull out the old element by gripping the end of the
element with channel lock pliers or a similar tool.
3. Install new o--rings on separator cap and separa-
tor element filter and oil lightly to make installa-
tion easier.
4. Insert and push the new element in place.
3,
Spec ific ations
. F ollow
WARNING
MAINTENANCE
5. Reinstall the cap. Hand--tighten using a 4" maxi-
mum length, 1/4" diameter pin in the radially
drilled hole.
MINIMUM PRESSURE/CHECK VALVE MAINTE-
NANCE
Refer t o
F igur e 6 --
4. Minimum pr es s ur e/c hec k v alv e
maintenance is minimal. The only parts which nor-
mally require replacement are the o--ring seal
around the piston and the valve seat on the check
valve. To replace any of the two parts, follow the pro-
cedure explained below.
Figure 6 ---4 Minimum Pressure/Check Valve
(P/N 604131)
* Repair Kit P/N 250030---226
Section 6
19

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents