Amp Draw Meter - Grizzly H2933 Instruction Manual

Double-head wide-belt sander
Hide thumbs Also See for H2933:
Table of Contents

Advertisement

Amp Draw Meter

The amperage draw meter (Figure 17) is located
above the control panel. Use the meter to monitor
the amperage draw on
forming sanding
operations.
As a general rule, always start with a small
load and work your way up. DO NOT work your
machine to its maximum load, where you can
hear the motor lose RPM; instead, make multiple
passes or install a coarser grit paper.
Amp load will be directly affected by many factors
such as feed rate, depth of cut, wood type, sand-
paper grit, and workpiece width. If the amp load is
in the red load range, the machine is overloaded
and motor damage will occur. Keep the amp load
in the green range during operation.
-24-
the machine while per-
Figure 17. Typical amp draw meter
and load chart.
NOTICE
DO NOT VOID WARRANTY! Keep the amp
draw within the GREEN load range shown
on the AMP LOAD CHART. If you operate
the sander in the RED load range, capacitor
or motor failure will occur and will not be
covered under warranty.
H2933/H2934/G0447/G0581 Wide Belt Sander

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

H2934G0447G0581

Table of Contents