TROUBLESHOOTING FLOW CHARTS
Electric dryer completely inoperative.
Note: If a fault code is displayed, the dryer will not operate.
Measure the voltage drop
between the red wire on the
thermal limiter and neutral.
0
Defective household
power supply or
broken wire between
dryer terminal block
and thermal limiter.
0
Defective thermal limiter.
Broken wire between
thermal limiter and the
control board.
mabe CONFIDENTIAL AND PROPRIETARY INFORMATION-NOT FOR PUBLIC DISCLOSURE.
Note: Always check wiring to the components.
Dryer completely
inoperative.
NO
Does the control beep or
the LED flash when the
START button is pushed?
120VAC
Measure the voltage drop
between the orange wire
on the thermal limiter and
neutral.
120VAC
0
Is an error code displayed?
YES
NO
120VAC
Measure the voltage drop
between pins 1 & 2 of J-4.
Defective
control board.
Measure the voltage drop
between pins 1 & 2 of the eight
pin plug of the wire harness to
the control board.
YES
Refer to error
code chart.
0
Defective door
120VAC
Defective control
board.
January 2007
switch.
21