9. General precautions
9.1 Handling
(a) When the panel kit and BLU kit are assembled, the panel kit and BLU kit should be attached to the
set system firmly by combining each mounted holes. Be careful not to give the mechanical stress.
(b) Be careful not to give any extra mechanical stress to the panel when designing the set, and BLU kit.
(c) Be cautious not to give any strong mechanical shock and / or any forces to the panel kit.
Applying the any forces to the panel may cause the abnormal operation or the damage to the panel
kit and the back light unit kit.
(d) Refrain from applying any forces to the source PBA and the drive IC in the process of the handling
or installing to the set. If any forces are applied to the products, it may cause damage or a
malfunction in the panel kit.
(e) Refrain from applying any forces which cause a constant shock to the back side of panel kit, the set
design and BLU kit. If any forces are applied to the products, it may cause an abnormal display, a
functional failure and etc.
(f) Note that polarizer could be damaged easily.
Do not press or scratch the bare surface with the material which is harder than a HB pencil lead.
(g) Wipe off water droplets or oil immediately. If you leave the droplets for a long time on the product, a
staining or the discoloration may occur.
(h) If the surface of the polarizer is dirty, clean it using the absorbent cotton or the soft cloth.
(i) Desirable cleaners are water or IPA (Isopropyl Alcohol).
Do not use Kenton type materials (ex. Acetone), Ethyl alcohol, Toluene, Ethyl acid or Methyl chloride.
These might cause the permanent damage to the polarizer due to chemical reaction.
(j) If the liquid crystal material leaks from the panel, this should be kept away from the eyes or mouth.
If this contacts to hands, legs, or clothes, you must washed it away with soap thoroughly and see a
doctor for the medical examination.
(k) Protect the panel kit and BLU Kit out of the static electricity. Otherwise the circuit IC could be
damaged.
- Reference : Process control standard of SDC
No.
Item
1
Ionizer
2
Carrying Roller
Equipment Ground
3
Resistance
MODEL
LSC460HJ03
All Equipment should be controlled under 150V.(Typ. 100V)
Carrying Roller should be controlled under 200V.
All Equipment Ground Should be less than 1ohm.
Doc. No
SAMSUNG Confidential
Control standard
Page
27 / 42