Download Print this page
Honeywell V4055A Manual

Honeywell V4055A Manual

On-off fluid power gas valve actuator
Hide thumbs Also See for V4055A:

Advertisement

APPLICATION

The V4055 Gas Valve Actuator, in combination with a V5034,
a
VE5000
, V5055 or V5097 Gas Valve, controls the gas supply
to commercial and industrial burners.

FEATURES

• The V4055 Actuator, when used with the V5034,
a
VE5000
, V5097 or V5055 Valve, is rated for final safety
shutoff service.
• The V4055 Actuator can be used with the characterized
guide model of the V5055 or V5097 Gas Valve to
enhance lightoff smoothness.
® U.S. Registered Trademark
Copyright © 2001 Honeywell • All Rights Reserved
V4055A,B,D,E
On-Off Fluid Power
Gas Valve Actuator
• The standard model has an opening time of
26 seconds at 60 Hz or 32 seconds at 50 Hz. A
fast-opening model is available with timings of
13 seconds at 60 Hz or 16 seconds at 50 Hz.
• Maximum closing time is one second, which meets
code, standard and insurer requirements.
• Models available with damper shaft, with or without
spring return; shaft extends out both sides and rides
in Teflon-like Delrin bushings; used with standard
7616BR Damper Crank Arm.
• Red OPEN indicator attached to actuator stem shows
when valve is even slightly open; yellow SHUT
indicator on valve stem shows only when gas valve is
fully closed.
• Models available with adjustable max flow limit switch.
• Ambient temperature rating is -40°F to +150°F (-40°C to
+66°C) for 60 Hz models and -10°F to +158°F (-23°C to
+70°C) for 50 Hz and 50/60 Hz models.
• Valve and actuator combinations can be mounted in
any position, with the exception of the 220 to 240 Vac,
50/60 Hz models, which are mounted vertically.
• Models available with factory-installed single pole
double throw (spdt) field-adjustable Auxiliary Switch.
Field-addable Auxiliary Switch kits are also available.
• Standard enclosure meets NEMA 1 (IP30)
requirements; models available with NEMA 4
weatherproof enclosure.
• V4055D and high pressure V4055E with
Proof-of-Closure Switch and V5055/V5097C or E with
valve seal overtravel interlock (double seal) to meet
specific code, standard and insurer requirements.
a
VE5000 is a European manufactured and approved valve for
European use only.
Application ........................................................................
Features ...........................................................................
Specifications ...................................................................
Ordering Information ........................................................
Installation ........................................................................
Wiring ...............................................................................
Checkout and Service ......................................................
PRODUCT DATA
Contents
1
1
2
2
5
7
8
60- 2309-10

Advertisement

loading

Summary of Contents for Honeywell V4055A

  • Page 1: Table Of Contents

    V5055 or V5097 Gas Valve to enhance lightoff smoothness. Contents Application ................ Features ................Specifications ..............Ordering Information ............Installation ................ Wiring ................Checkout and Service ............® U.S. Registered Trademark Copyright © 2001 Honeywell • All Rights Reserved 60- 2309-10...
  • Page 2: Specifications

    Honeywell, 1885 Douglas Drive North Minneapolis, Minnesota 55422-4386 In Canada—Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive, Scarborough, Ontario M1V 4Z9. International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A.
  • Page 3 V4055A,B,D,E ON-OFF FLUID POWER GAS VALVE ACTUATOR Table 3. V4055A,D Electrical Ratings. Opening (Standard) Opening (Fast) Holding Voltage and Frequency Inrush Inrush (VA) (VA) — 43.0 0.91 — 58.0 1.30 10.4 0.16 100/50-60 — 33.0 — 43.0 0.91 0.14 100/50-60 120/60 50.0...
  • Page 4 V4055A,B,D,E ON-OFF FLUID POWER GAS VALVE ACTUATOR Accessories: 7616BR Damper Crank Arm (damper arm and clip). 133533A Short Stem Adapter for mounting actuator on V5034 Q5055A1001 Adapter Assembly (adapts ITT General V710 Valve. Gas Valve to accept Honeywell gas valve actuators.
  • Page 5: Installation

    V4055A,B,D,E ON-OFF FLUID POWER GAS VALVE ACTUATOR INSTALLATION To install the switches: 1. Remove the actuator faceplate (two screws). 2. Remove the silver-colored barrier to expose the When Installing This Product... actuator stem. 1. Read these instructions carefully. Failure to follow them 3.
  • Page 6 V4055A,B,D,E ON-OFF FLUID POWER GAS VALVE ACTUATOR Replace V4034 Actuator on V5034 Valve The V4055 is rated for ambient temperatures down to -40°F (-40°C) for 60 Hz models, or -10°F (-23°C) for 50 Hz and 50/60 Hz models, and does not require a heater. Remove all IMPORTANT the wiring associated with the heater.
  • Page 7: Wiring

    V4055A,B,D,E ON-OFF FLUID POWER GAS VALVE ACTUATOR WIRING WARNING Electrical Shock Hazard. Can cause serious injury or death. Disconnect power supply before making wiring connections to prevent electrical shock and equipment damage. PROOF-OF-CLOSURE SWITCH Wiring must comply with all applicable electrical codes, AUXILIARY ordinances and regulations.
  • Page 8: Checkout And Service

    V4055A,B,D,E ON-OFF FLUID POWER GAS VALVE ACTUATOR CHECKOUT AND SERVICE Checkout After the installation is complete, cycle the valve several times with the manual fuel shutoff cock closed before testing the CAUTION system in actual operation. Equipment Damage Hazard. Service Unskilled technicians can cause equipment damage.

This manual is also suitable for:

V4055bV4055dV4055e