TYPE OF EXHIBIT:
FCC PART:
MANUFACTURER:
MODELS:
TYPE OF UNIT:
FCC ID:
DATE:
Included in this exhibit are draft copies of the User Manual for RITRON Models RQT-451 and RQA-451
UHF-FM Voice Message Transmitters.
These manuals provide the end user with installation and operating instructions.
Signed:
Michael A. Pickard - Project Engineer
INSTALLATION AND OPERATING INSTRUCTION MANUAL
2.1033 (c)(3)
RITRON, INC.
505 West Carmel Drive
Carmel, IN 46032
RQA-451, RQT-451
UHF-FM Voice Message Transmitter
AIERIT32-451
January 14, 2011
RQT-451_UserMan.pdf

Advertisement

Table of Contents
loading

Summary of Contents for Ritron Quick Talk RQA-451

  • Page 1 FCC ID: AIERIT32-451 DATE: January 14, 2011 Included in this exhibit are draft copies of the User Manual for RITRON Models RQT-451 and RQA-451 UHF-FM Voice Message Transmitters. These manuals provide the end user with installation and operating instructions. Signed: Michael A.
  • Page 2 Ritron Publication 145000081 Rev. A 01-11 © 2010 Ritron, Inc. All rights reserved. Ritron, Patriot, Jobcom, OutPost, GateGuard, Quiet Call and Quick Assist are registered trademarks of Ritron, Inc. Quick Talk, Liberty and RadioNexus are trademarks of Ritron, Inc. Call 800-USA-1-USA for the right Wireless Solutions to your communication needs.
  • Page 3: Table Of Contents

    If you are unsure whether your Monitor 4-20mA Sensor Current Loop with Quick Talk Analog installation will be safe, contact an Input.....................14 experienced electrician or electronics Ritron, Inc. Limited Warranty ............15 technician. For assistance, call RITRON at 800-872-1872, or go to www.ritron.com...
  • Page 4: About The Quick Talk

    Quick Talk The Quick Talk is easily programmed to transmit on Ritron pioneered the use of Color Dots on radios to either an existing or a new radio frequency, with the identify frequencies.
  • Page 5: Quick Talk Tm Wireless Voice Alarm Reporter Features

    Quick Talk and it’s Call Ritron; we will be glad to help you. For most attached antenna for the best range, at an unobstructed applications, this manual should cover everything you and elevated position.
  • Page 6: Identification Of Quick Talk Controls And Connectors

    24-AWG In-wall Type CM, Cat. No. 278-874, connector to the radio printed circuit board. or equivalent size round cable (0.114 — 0.250” diameter). If you cannot find suitable wire, call Ritron at 800-872-1872. External Audio Input Allows input to the Quick Talk...
  • Page 7: Description

    TX Alert Tone • Your assigned frequency is shown on your FCC Station License. The RQT can transmit an alert tone • Call your radio dealer or Ritron for help if you cannot determine your before and after each voice message transmission.
  • Page 8: Compand

    Debounce / Holdoff Time – specifies the debounce time or holdoff time described above. This time is programmed independently for the OPEN and CLOSED conditions. For assistance, call RITRON at 800-872-1872, or go to www.ritron.com...
  • Page 9: Message Repeat

    Inputs 1-4 Closed/Low Repeat forever TX Alert Tone Wait Time between Transmissions Inputs 1-4 Open/High On change only Battery Saver Inputs 1-4 Closed/Low On change only Low Battery Message Power Fail Message For assistance, call RITRON at 800-872-1872, or go to www.ritron.com...
  • Page 10: Programming Your Quick Talk

    12.5 kHz narrow band channel bandwidth. Many of the Frequency Table Codes programmed in your compatible Ritron radios are for 25 kHz wide band channels. If these codes are selected when programming your Quick Talk radio, the programmer will automatically update to the equivalent 12.5 kHz code.
  • Page 11 Use Code “44” to program No Tone for systems without a Coded Squelch Interference Eliminator feature. TABLE 5: Digital Quiet Call Codes Code Code Code Code Code Code Code Code Code For assistance, call RITRON at 800-872-1872, or go to www.ritron.com...
  • Page 12: Recording Your Quick Talk Tm Voice Messages

    If you decide later to Select the messages you will be recording. use additional inputs, all messages will have to be re- Enter Message Delay on TX time. recorded. For assistance, call RITRON at 800-872-1872, or go to www.ritron.com...
  • Page 13: Test Your Quick Talk Programming

    If Repeat Message Transmissions has been programmed for more than one transmission, the Quick Talk transmitter will again be activated and Steps 1 – 8 will be repeated for the programmed number of transmissions. For assistance, call RITRON at 800-872-1872, or go to www.ritron.com...
  • Page 14: Installing The Quick Talk

    7,000 voice messages over a sealed strain relief to provide weather period of one year before the batteries will need resistance. to be replaced. For assistance, call RITRON at 800-872-1872, or go to www.ritron.com...
  • Page 15: Test Your Switch's Open And Closed Conditions

    This is because it draws approximately 7 mA continuously with this setting and will rapidly drain the batteries. NOTE: DO NOT disable the Battery Saver unless you need to detect very fast changes on the inputs. For assistance, call RITRON at 800-872-1872, or go to www.ritron.com...
  • Page 16: Automatic Low Battery Alert Message

    Use the PC Programmer to set the Quick Talk for External Power. If the factory recorded “Power Fail” message is not adequate, record a new Power Fail message. Use Ritron #RPS-203 Power Supply (11-15 VDC, 200 mA), or equivalent, to power the Quick Talk . The Quick Talk requires 11-15 VDC, 200 mA minimum.
  • Page 17: Monitor 4-20Ma Sensor Current Loop With Quick Talk Analog 7. Input

    Connect the output of the 4-20 mA current loop device to the positive (+) wire of the Input connection. Program the desired Input for Analog Input operation and for the calculated Analog Setpoints. Record an Input OPEN and Input CLOSED message for the associated Input. For assistance, call RITRON at 800-872-1872, or go to www.ritron.com...
  • Page 18: Ritron, Inc. Limited Warranty

    • Installation, maintenance or service of the product, unless this is covered by a separate written agreement with RITRON; • Any products not furnished by RITRON which are attached or used with the covered product, or defects or damage from the use of the covered product with equipment that is not covered (such as defects or damage from the charging or use of batteries other than with covered product);...
  • Page 19 Ritron Publication 14500079 Rev. A 01-11 © 2010 Ritron, Inc. All rights reserved. Ritron, Patriot, Jobcom, OutPost, GateGuard, Quiet Call and Quick Assist are registered trademarks of Ritron, Inc. Quick Talk, Liberty and RadioNexus are trademarks of Ritron, Inc. Call 800-USA-1-USA for the right Wireless Solutions to your communication needs.
  • Page 20 Ritron, Inc. Limited Warranty ............14 ® (Digital Quiet CaII Interference Eliminator); Message transmission schedules and limits. • Connection and use of an external 12 Volt DC power supply. • Limited One-year Factory Warranty. For assistance, call RITRON at 800-872-1872, or go to www.ritron.com...
  • Page 21: About The Quick Assist

    Commission, Code of Federal Regulations; 47 CFR Population/Uncontrolled limits. Antennas other than §§ 2 sub-part J. those available from RITRON have not been tested for compliance and may or may not meet the exposure • American National Standards Institute (ANSI) / limits at the distances given.
  • Page 22: Frequently Asked Questions About Quick Assist Programming

    ® audible signaling formats: QC (Quiet Call What if I don’t find what I need in this manual? Interference Eliminator), and DQC (Digital Quiet Call Ritron (317-846-1201): we will be glad to help you. For ® ® Call Interference Eliminator). Both Quiet Call...
  • Page 23: Installation / Replacement Of Batteries

    Secure the case halves with the four corner screws and re-install on the wall or mounting surface. NOTE: Be sure to properly dispose of the used batteries ® removed from the Quick Assist For assistance, call RITRON at 800-872-1872, or go to www.ritron.com...
  • Page 24 Out audio from your computer. ® disassemble the Quick Assist unit; doing so risks damage to the unit and voiding the manufacturer’s warranty. Microphone Microphone for recording voice messages. FIG-1: CONTROLS & CONNECTIONS For assistance, call RITRON at 800-872-1872, or go to www.ritron.com...
  • Page 25: Frequency Table

    The Quick Assist can transmit an alert tone before and after each voice • Call your radio dealer or Ritron for help if you cannot determine your message transmission. radio’s receiver frequency. For assistance, call RITRON at 800-872-1872, or go to...
  • Page 26: Compand

    This is necessary for momentary push button The beginning and ending beeps are added operation. ® automatically to attract attention to Quick Assist transmissions if the TX Alert Tone feature has been set. For assistance, call RITRON at 800-872-1872, or go to www.ritron.com...
  • Page 27: Quick Assist ® Default Programming

    Low Battery “Low battery” Number of Times Recorded Message is repeated on each Transmission 1 time Number of Times the Transmission is sent 2 times Wait Time between Transmissions 30 seconds For assistance, call RITRON at 800-872-1872, or go to www.ritron.com...
  • Page 28: Programming Your Quick Assist

    The Quick Assist transmitter operates exclusively on a 12.5 kHz narrow band channel bandwidth. Many of the Frequency Table Codes programmed in your compatible Ritron radios are for 25 kHz wide band channels. If these ® codes are selected when programming your Quick Assist radio, the programmer will automatically update to the ®...
  • Page 29 Use Code “44” to program No Tone for systems without a Coded Squelch Interference Eliminator feature. TABLE 5: Digital Quiet Call Codes Code Code Code Code Code Code Code Code Code For assistance, call RITRON at 800-872-1872, or go to www.ritron.com...
  • Page 30: Recording Your Quick Assist Voice Messages

    The Quick Assist will transmit the message on ® regularly change Quick Assist batteries, the factory- the transmit frequency associated with the input programmed message may be sufficient for your application. selected. For assistance, call RITRON at 800-872-1872, or go to www.ritron.com...
  • Page 31: Test Your Quick Assist Programming

    10. If at any time during this sequence the front panel button is held down until the LED begins flashing rapidly, the RQA will transmit the Reset Message and the sequence will be terminated. For assistance, call RITRON at 800-872-1872, or go to www.ritron.com...
  • Page 32: Installing The Quick Assist

    Estimated Battery Life: Starting with a fresh set keyhole slots. ® of AA alkaline batteries, Quick Assist transmit about 7,000 voice messages over a period of one year before the batteries will need to be replaced. For assistance, call RITRON at 800-872-1872, or go to www.ritron.com...
  • Page 33: Record Custom Voice Messages

    External Power. If the factory recorded “Power Fail” message is not adequate, record a new Power Fail message. ® Use Ritron #RPS-203 Power Supply (11-15 VDC, 200 mA), or equivalent, to power the Quick Assist . The Quick ®...
  • Page 34: Ritron, Inc. Limited Warranty

    • Installation, maintenance or service of the product, unless this is covered by a separate written agreement with RITRON; • Any products not furnished by RITRON which are attached or used with the covered product, or defects or damage from the use of the covered product with equipment that is not covered (such as defects or damage from the charging or use of batteries other than with covered product);...

This manual is also suitable for:

Quick talk rqt-451

Table of Contents