Emergency, test and air cleaning operation

TEST
Installed on standard units and units with
optional active carbon filter/electro static
filter.
Emergency
When the remote controller is lost, damaged or the battery is
discharged, the EMERGENCY switch can be used to run the unit.
• Change the switch from REMOTE to EMER position.
- The unit is operated automatically according to the room
temperature by selecting cooling heating operation.
Test Operation
This operation is used when checking after installing the unit.
• Change the switch to TEST position.
• Change the switch to REMOTE position after checking.
• Changing the operation by the remote controller during the test
operation is impossible.
• Don't use the TEST switch in normal operation.
Air Cleaning Operation
Whenever indoor fan is on, the optional electric air cleaner is on
and the AIR CLEAN lamp in the unit is on.
• If the Front Grille of unit is opened, the air cleaner is off and
CHECK lamp in the unit is on.
- Press RESET button in the unit before you close
the Front Grille.
REMOTE
EMER.
Electric air cleaner
TEST
EMER.
Installed on units with optional electric air
cleaner.
• The setting conditions of emergency operation are as follows.
- Operation mode: AUTO
- Preset temperature: 25°C
- Fan speed: AUTO
- Timer mode: Continuous
- Discharge air direction: Set automatically according to operation
mode. (See p. 12.)
• The setting conditions of test operation are as follows.
- Operation mode: COOL
- Fan speed: HIGH
- Timer mode: Continuous
- Discharge air direction: AUTO SWING
(option filter)
Information for option filters
• Option filters
• These filters eliminate microscopic dust, virus and smoke and prevent
growth of mold and virus to clean the room air more effectively than
the air filters.
ENGLISH
REMOTE
AIR
CLEAN
RESET
Electro static filter
(option filter)
Active carbon filter
(option filter)
Electric air cleaner (53QNL012 only)
Active carbon filter/Electro static filter