Installation
Guide
Models covered
RS485 StarCard including optional
Telemetry Protocol Converter
This manual covers software version CONV1_V14. Refer to addendum if using different software.
BBV RX450/550, CBC SMD20/Star MD2000/Sanyo VCC9200P, Chugai/Ganz ZC-S122/123,
Dennard 2050, JVC 676, Mark Mercer, Molynx 250/260, Panasonic CS850/860, Pelco P , Pelco D,
360 Vision, VCL, Vicon Surveyor, Vista PowerDome, Samsung 641/643 dome 421P camera, Meyertech
ZVR510 VICTA protocol.
Building Block Video Ltd.,
17 Apex Park,
Diplocks Industrial Estate,
Hailsham, East Sussex, BN27 3JU UK.
Tel: +44(0)1323 842727
Fax: +44(0)1323 842728
Support: +44(0)1323 444600
www.bbvcctv.com
BBV
BBV

Advertisement

Table of Contents
loading

Summary of Contents for BBV RS485

  • Page 1: Installation Guide

    Telemetry Protocol Converter This manual covers software version CONV1_V14. Refer to addendum if using different software. BBV RX450/550, CBC SMD20/Star MD2000/Sanyo VCC9200P, Chugai/Ganz ZC-S122/123, Dennard 2050, JVC 676, Mark Mercer, Molynx 250/260, Panasonic CS850/860, Pelco P , Pelco D, 360 Vision, VCL, Vicon Surveyor, Vista PowerDome, Samsung 641/643 dome 421P camera, Meyertech ZVR510 VICTA protocol.
  • Page 2 If you are not sure of the type of power supply you intend to use, consult your equipment dealer or local power company. For units intended to operate from battery power or other sources, refer to operating instructions. RS485 Star Card Manual V14 4Feb04.doc Page 2/29...
  • Page 3 The “exclamation point” symbol inside an equilateral triangle is used to alert the user of this equipment to important operating and maintenance (servicing) instructions in the literature accompanying the appliance. RS485 Star Card Manual V14 4Feb04.doc Page 3/29...
  • Page 4 Power Requirements 9Vdc 500mA Inputs 2 or 4 wire RS485 (switch selectable) Outputs 8 * 2 or 4 wire RS485 (switch selectable – DEFAULT 4 WIRE) Maximum cable run approx. 4000 Feet/1200M Facilities LED as power and data indication Other Outputs RS232 monitor output via chassis mounted DB9 connector.
  • Page 5 Eight individual outputs are provided. Each output can be connected to a single dome/receiver or up to 32 domes/receivers wired as a daisy chain. When the domes/receivers are wired as a daisy chain, the last unit’s RS485 must be terminated and the intermediate units must be un-terminated. With a single dome connected to each output, the RS485 must be terminated.
  • Page 6 Internal view of starcard showing switch settings 00007-3 Starcard PCB Switches SW1 - RS485 line termination for outputs 1 - 4 ON = termination ON (Default) SW1/1 & 1/2 = Output 1 termination SW1 setting showing termination ON SW1/3 & 1/4 = Output 2 termination SW1/5 &...
  • Page 7 Panasonic Specific notes: FS616 - A single RS485 output is available. Connect the RS485 output to the star card as shown. SX350 - Two RS485 outputs are available. SX550/850 - Not required as each matrix RS485 output card has eight individual outputs.
  • Page 8 Panasonic Specific Notes: FS616 - A single RS485 output is available. Connect the RS485 output to the star card as shown. SX350 - Not compatible with 4 wire telemetry. SX550/850 - Not required as each matrix RS485 output card has eight individual outputs.
  • Page 9 IMPORTANT NOTE. When using the protocol converter, ensure that the starcard is set for 4 wire telemetry using SW3/8 OFF. RS485 data IN to MASTER RA/RB or BBV TELEMETRY IN with a TX1500 and data OUT to domes on STAR TRA/TRB.
  • Page 10 SW2(OUT) = A3 MARK MERCER V7.3:9600,N,8,1 A debug mode can also be selected which provides detailed information for each command received. Whilst trouble shooting BBV engineers may ask you to use this mode with a laptop or other PC. BBV Protocol Converter V13 www.bbvcctv.com...
  • Page 11 DENNARD 2050 MARK MERCER VCL TP PANASONIC CS850/860 BBV RS485 (RX457/557) JVC TKC676 BBV RX450/550 GANZ ZCS122/123 MOLYNX 250/260 PELCO D/P 360 VISION CBC SMD20 VICON VISTA POWERDOME SAMSUNG SCC641/643 MEYERTECH VICTA RS485 Star Card Manual V14 4Feb04.doc Page 11/29...
  • Page 12 TX1500 Procedure Pelco Procedure 180 Pan U turn 1 # or WASH SAVE PRESET 95 Start current dome’s patrol 1 PATROL GOTO PRESET 97 Start ALL DOMES patrol 2 PATROL GOTO PRESET 98 RS485 Star Card Manual V14 4Feb04.doc Page 12/29...
  • Page 13 Set the dome address using the DIL switch to match the number of the camera input of the TX1500. Ensure that any dome at the end of a daisy chained RS485 run are have the RS485 terminated and the intermediate domes have the RS485 determinated.
  • Page 14 This command will clear all dome configuration including preset positions. Define learned tour 5 – START SAVE PRESET 56 Define learned tour 5 – STOP SAVE PRESET 57 Enable AUTO180 pan flip SAVE PRESET 58 RS485 Star Card Manual V14 4Feb04.doc Page 14/29...
  • Page 15 The 4 way dome switch must be set to 4 wire telemetry with switches 2,3,4 OFF. The RS485 cable requires termination at the end of the run by setting switch 1 ON. The Panasonic CS850/860 protocol conversion is only available when controlled using BBV RS485 telemetry.
  • Page 16 A total of up to 96 domes are supported with a maximum of 32 domes per star output. To display the current dome’s menu, press either 1# with the BBV Tx1500 or SAVE PRESET 95 using Pelco-P or Pelco-D protocol. Use standard PAN/TILT and where required ZOOM to navigate through the menus.
  • Page 17 TX1500. Ensure that domes at the end of the RS485 run are terminated by turning switch 8 ON and the intermediate domes have the switch 8 OFF.
  • Page 18 Set the receiver address switches to match the number of the camera input of the TX1500. Molynx receivers can only be controlled when using BBV telemetry into the StarCard ie from the BBV Tx1500 matrix. Control of the receiver auxiliary relays is possible using the Tx1500 Wash, Wipe and Lights keys.
  • Page 19 GOTO PRESET 98 This allows control of Pelco P and Pelco D units. Please ensure that the baud rate and parity are set correctly. Generally Pelco P uses 9600,N,8,1 and Pelco D uses 2400,N,8,1. RS485 Star Card Manual V14 4Feb04.doc Page 19/29...
  • Page 20 Set the dome address using the DIL switch to match the number of the camera input of the TX1500. Ensure that the dome at the end of a daisy chained RS485 run has the RS485 terminated and the intermediate domes have the RS485 de-terminated.
  • Page 21 Set the dome address using the DIL switch to match the number of the camera input of the TX1500. Ensure that the dome at the end of a daisy chained RS485 run has the RS485 terminated and the intermediate domes have the RS485 de-terminated.
  • Page 22 Set the dome address using the DIL switch to match the number of the camera input of the TX1500. Ensure that the dome at the end of a daisy chained RS485 run has the RS485 terminated and the intermediate domes have the RS485 de-terminated.
  • Page 23 Set the dome address using the DIL switch to match the number of the camera input of the TX1500. Ensure that any dome at the end of a daisy chained RS485 run are have the RS485 terminated and the intermediate domes have the RS485 de-terminated.
  • Page 24 Set the dome address using the DIL switch to match the number of the camera input of the TX1500. Ensure that any dome at the end of a daisy chained RS485 run are have the RS485 terminated and the intermediate domes have the RS485 de-terminated.
  • Page 25 Connect the camera RS485 Data+ to Converter TRA and Data- to Converter TRB. Ensure that BAUD RATE is set to 9600 and RS485 ADDR is set to match the video input on the Tx1500 matrix. The buttons on the rear of the camera allow menu access.
  • Page 26 Meyertech ZVR-510 receiver with VICTA protocol from BBV telemetry only. Connect receiver 422 RX+ to Converter TRA and 422 RS- to Converter TRB. Set the receiver address to match the number of the camera input of the TX1500. The following functionality is provided.
  • Page 27 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Starcard SW3 setting Control System RX485 terminated 4 WIRE On single direction RS485, multiple StarCards can be daisy chained to provide multiple outputs. RS485 Star Card Manual V14 4Feb04.doc Page 27/29...
  • Page 28 Rx550 Panasonic SX-350 Wiring Details SCREEN SCREEN SCREEN The SX350 has two individual RS485 ports. Each port may be connected to a seperate StarCard. The diagram on the left shows a connection to port 2. StarCard StarCard StarCard RS485 Star Card Manual V14 4Feb04.doc...
  • Page 29 RS485 connection details (Star Card must be in 4 wire mode) DM- DB9F Rx452/552 DOME Ground must be connected with DS2 DM Digital Sprite/DSL/DS2 RS485 Wiring details StarCard StarCard StarCard Camera 1 DC Head Camera 2 AC Head Camera 3 DC Head...