Pin 10
GND
Pin 11
RX-
Pin 12
RX+
Pin 13
TX-
Pin 14
TX+
RJ 45 cabling recommendation :
RJ45 plug pinout is compliant with 10 base T , IEEE802.3 Specification.
Pinout
1
TD(+) Transmit Data Plus
(Output)
2
TD(-) Transmit Data Minus
(Output)
3
RX(+) Receive Data Plus
(Input)
4
No connection
5
No connection
6
RX(-) Receive Data Minus
(Input)
7
Ground protection ( option )
8
No connection
SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
18
5
6
7
8
Ground for Ethernet Interface (LAN 10/100 Mbps)
Receive negative Ethernet
Receive positive Ethernet
Transmit negative Ethernet
Transmit positive Ethernet
Signals
9
10 11 12 13 14
EIA/TIA
T568B color
T568A color
White Orange
White Green
Orange
White Green
White Orange
Blue
White blue
Green
White Brown
White Brown
Brown
EIA/TIA
Corel L120
color
Grey
Green
White
Pink
Blue
Orange
White blue
Yellow
Orange
Blue
Purple
Brown
Brown