LG 42PX4D Owner's Manual page 93

Hide thumbs Also See for 42PX4D:
Table of Contents

Advertisement

Owner
's Manual
93
External
Control
Device
Setup
Set ID
Set ID
Use this function
to
specify
a
TV ID number.
Refer
to
'Real Data
Mapping'.
See page 94.
?
Baud
rate
:
9600
bps (UART)
?
Data
length
:
8 bits
?
Parity
:
None
*
Use
a
crossed
(reverse)
cable.
?Stopbit:1bit
?
Communication code
:
ASCII code
Communication Parameters
Communication Parameters
1. Press the MENU button and then
use
/
button
to
select the SETUP
menu.
2. Press the
button and then
use
/
button
to
select SET ID.
3. Press the
button and then
use
/
button
to
adjust
SET
ID to choose the
desired TV ID number. The
adjustment
range of SET ID is 1
~
99.
4. Press EXIT button to return to TV
viewing
or
press MENU button
to return to
the
previous
menu.
Transmission
*
[Command 1]:
First command
to
control the
set.
(j
or
k)
*
[Command 2]:
Second command
to
control the
set.
*
[Set ID]:
You
can
adjust
the
set
ID
to
choose desired TV ID
number in
Setup
menu.
Adjustment
range is 1
~
99. When
selecting
Set ID
'0',
every connected the
TV is controlled. Set ID is indicated
as
decimal
(1~99)
on menu
and
as
Hexa decimal
(0x0~0x63)
on
transmission/receiving protocol.
*
[DATA]:
To transmit command data.
Transmit 'FF' data
to
read
status
of command.
*
[Cr]: Carriage
Return
ASCII code '0x0D'
*
[
]:
ASCII code
'space (0x20)'
[Command1][Command2][ ][Set ID][ ][Data][Cr]
T
T ransmission
/
Receiving
Protocol
ransmission /
Receiving
Protocol
OK
Acknowledgement
*
The TVr transmits ACK
(acknowledgement)
based
on
this
format when
receiving
normal data. At this
time,
if the data
is data read
mode,
it indicates
present
status
data. If the
data is data write
mode,
it
returns
the data of the PC
com
-
puter.
[Command2][ ][Set ID][ ][OK][Data][x]
Error
Acknowledgement
*
The TV transmits ACK
(acknowledgement)
based
on
this
format when
receiving
abnormal data from non-viable
functions
or
communication
errors.
[Command2][ ][Set ID][ ][NG][Data][x]
Data
1:
Illegal
Code
2: Not
supported
function
3: Wait
more
time
01. Power
k
a
0~1
02.
Input
Select
k
b
0~9
03.
Aspect
Ratio
k
c
*
04. Screen Mute
k
d
0~1
05. Volume Mute
k
e
0~2
06. Volume Control
k
f
0~64
07. Contrast
k
g
0~64
08.
Brightness
k
h
0~64
09. Color
k
i
0~64
10. Tint
k
j
0~64
11.
Sharpness
k
k
0~64
12. OSD Select
k
l
0~1
13. Remote Control Lock Mode
k
m
0~1
14. PIP/POP/Twin
k
n
0,1,2,5
15. PIP Position
k
q
0~3
16. Treble
k
r
0~64
17. Bass
k
s
0~64
18. Balance
k
t
0~64
19. Color
Temperature
k
u
0~2
20. PIP
Input
Source
k
y
0~3
21. ISM Method
j
p
1,2,4,8
22. Low Power
j
q
*
23. Orbiter Time
Setting
j
r
1~FE
24. Orbiter Pixel
Setting
j
s
1~3
COMMAND 1 COMMAND 2
DATA
(Hexadecimal)
25. Channel
Tuning
m
a
01~87 01~87
00~FE 00~FF
00~FF
00~FF
26. Channel Add/Del
m
b
00
~
01
27.
Key
m
c
*
28.
Input
Select
xb
*
29. PIP
Input
Select
x
y
*
COM-
MAND 2
COM-
MAND 1
DATA 0
(Hexadecimal)
DATA 1
(Hexadecimal)
DATA 2
(Hexadecimal)
DATA 3
(Hexadecimal)
Command Reference List
Command Reference List
DATA 4
(Hexadecimal)
DATA 5
(Hexadecimal)