Data Save ........................31 Set ..........................33 Section 4. Specifications Section 5. Troubleshooting Appendix A. 910FS Fusion Splicer Cleaning Appendix B. Practice Splicing Appendix C. Greenlee Splice-on Connectors Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070...
Keep this manual available to all personnel. Replacement manuals are available upon request at no charge at www.greenlee.com. All specifications are nominal and may change as design improvements occur. Greenlee Textron Inc. shall not be liable for damages resulting from misapplication or misuse of its products.
Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. Failure to observe this warning could result in severe injury or death. Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070...
Page 5
• Liquid or foreign matter falls into cabinet. • Splicer is damaged or dropped. If these faults occur, return unit to Greenlee service center for repair. Leaving splicer in a damaged state could cause equipment failure, electric shock or fire, and could result in severe injury or death.
Page 6
This may result in electric shock, splicer malfunction, or poor splicing performance. Failure to observe these warnings could result in severe injury or death. Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070...
Page 7
Greenlee. • If charge did not complete in four hours or the “CHARGE” LED is constantly on, stop charging immediately and call Greenlee service center for repair. Failure to observe these warnings could result in severe injury or death. Battery safety: •...
Page 8
• This equipment must be repaired or adjusted by a qualified technician or engineer. Incorrect repair may cause fire or electric shock. Contact Greenlee service center for repair. Failure to observe these precautions may result in injury and may damage the unit.
910FS Splicer Section 1. Identification Components of Splicer Tube Heater Cooling Tray Wind Protector Keypads Port RS-232 Battery Port Compartment Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070...
Page 10
910FS Splicer Top View Wind Protector Mirror Electrode Cover Fiber Adapter Guide Groove V-groove Fiber Adapter Electrode Cover Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070...
Section 2. Operation Setup Installing Battery in Splicer The 910FS can be powered by an external power adapter and battery. Inserting the Battery Remove the protective cover from the battery contacts. Insert the battery into the battery compartment until it clicks into place.
The automatic arc calibration function works in AUTO modes only. It is not active in the standard splice modes. When using those modes, performing arc calibration before splicing is strongly recommended. Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070...
• When protection sleeve core tube is longer than the length of outer sheath, cut off excess sleeve to avoid micro bend after heating. Failure to observe these precautions may result in injury and may damage the unit. Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070...
Page 14
1. Open the wind protector and install the fiber adapters into the splicer, making sure the fiber is positioned into the center of the V-grooves. 2. Close the wind protector. Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070...
To ensure a good splice, the optical fiber is observed with the image processing system equipped in the 910FS. However, in some cases the image processing system cannot detect a faulty splice. Visual inspection with the monitor is often necessary for better splicing yield.
Page 16
“Maintenance” menu. Select “Arc Calibration.” 3. Follow the on-screen prompts. Note: It might be necessary to push up to three times until “the arc adjust OK” prompt is achieved. Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070...
5. Visually inspect the finished sleeve to verify that no bubbles or debris/dust is present in the sleeve. Cooling Tray Place the splice into the cooling tray on the back of the 910FS splicer. Splice-on Connectors The 910FS uses the Greenlee version of splice-on connectors. The 910FS currently supports SC, LC, FC, and ST versions (both PC and APC finish, where applicable).
910FS Splicer Upgrading Software The 910FS software can be upgraded using the online software upgrade tool at www.greenlee.com. Button Functions Button Description Turns the splicer ON/OFF Menu key Enter key Return/Exit key Left key Right key/Help key Up key/Bright key for LCD...
There are six main menus: 1. Splice Mode Menu (S–Mode) 2. Heater Mode Menu (H–Mode) 3. Maintenance 4. Splice Set 5. Data Save 6. Set Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070...
Page 21
It is the fastest splice mode at 9 seconds splicing time. This mode process does not analyze fiber geometry. BLANK 12~60 User can assign these as their own custom splicing profiles. (other modes) Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070...
Press p or q to select the parameter to be modified, and then press to enter the parameter setting. Press p or q to modify the parameter, and then press to confirm. Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070...
Page 23
• Arc2 ON Time: Set or disable the Arc2’s working (arcing) duration. • Arc2 OFF Time: Set or disable the Arc2’s off duration. • Rearc Time: Set or disable the duration of the Rearc. Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070...
Page 24
The user will have to perform careful experiments with their individual fibers to obtain optimum results. Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070...
Sets Finish Temp (Finish Temperature): When heater approaches this temperature, the buzzer beeps, announcing the sleeve is cooled down and is ready to be removed from the heater. Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070...
Page 26
• Heater Mode: Enter the mode as center and sides activated or center only activated. Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070...
910FS Splicer Maintenance The 910FS can perform routine maintenance. In “Maintenance”, the operator can calibrate arc, set motor drive, calibrate motors, adjust screen, replace electrodes, and stabilize electrodes. Arc Calibration Used to calibrate arc function to obtain the best splicing results when a splicing session is first started or if the splicing environment has changed.
Page 28
910FS Splicer Cleaning the Electrodes It may be necessary to clean the electrodes if the arc calibration fails or if the 910FS is not splicing properly. 1. Remove the electrodes and clean the electrodes using the electrode polisher. 2. Insert the electrode tip into the hole of the electrode polisher and gently rotate the electrode.
Page 29
1. Turn splicer OFF. 2. Replace the electrodes. 3. Power splicer ON. 4. Select “Replace Electrodes” from menu. 5. Follow on-screen prompts. (This process may take 10 minutes.) Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070...
Splice setting options include splicing control, display settings, and splice limit settings for all splice profiles. Navigate to the “Splice Set” icon and press Each menu item can be enabled or disabled per the user’s preference. Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070...
910FS Splicer Data Save The 910FS stores up to 5000 splicing results, which can be downloaded via the USB port. Navigate to the “Data Save” icon and press to access. Splice Memory The Splice Memory function allows the user to display, export, and clear splice memory.
Page 32
Clear Arc Count The Clear Arc Count function allows the user to clear current arc counts from the last clearance. Press to confirm, and press to exit. Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070...
The Maintenance INFO function allows the user to check total fusion count, software version, and serial number information. This menu is used to set system settings. Language Press p and q to set the desired language. Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070...
Page 34
The Beep Switch function allows the user to enable or disable the splicer beeper. Screen Direction The Screen Direction function allows the user to change the display direction for front- or back-facing position. Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070...
Page 35
Use p and q to select the “Set” icon, and then navigate to the “LCD Brightness” tab. Use p and q to adjust the brightness. Then press to confirm. Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070...
Sensor Value Displays pressure (XXX Hpa), and temperature (XXX °C). Load Default Press to restore the 910FS to default. Password Press to enter the “Password” menu. Select “Password Lock”, and press enable or disable password function. Greenlee / A Textron Company...
Page 37
The super password is obtained from Greenlee customer service. For each restart, the [XX] is changed, so the user cannot use the last super password again and needs to contact customer service.
180x160x155 mm (7.1 x 6.3 x 6.1 in) Splice-on Connector SC, LC, FC, and ST * Insertion loss is for cut and re-splice of identical fibers. Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070...
Fiber stuffing too small. Perform “Motor Calibration”. Prefuse power too high, or Decrease “Prefuse Power” prefuse time too long. and/or “Prefuse Time”. continued on next page Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070...
Page 40
(different diameters) are spliced. This does not affect splice quality, such as splice loss or tensile strength. Note: If the user is getting high splice losses, make sure that the 910FS is not in Splice Mode #10, which is used to make attenuator splices.
• Check the condition of fiber cleaver. If the blade is worn, rotate the blade to a new position. Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070...
Page 42
Magnet needs to be factory replaced. windshell is closed Notified to replace Electrodes require calibration or Stabilize electrodes as per Menu 3; replace electrodes replacement. electrodes. Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070...
Page 43
The MFD mismatch function does not work for certain types of specialty fibers. In these cases, set the “MFD Mismatch” to OFF. Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070...
910FS Splicer Appendix A. 910FS Fusion Splicer Cleaning Precautions When Cleaning 910FS and 910CL • Turn off splicer. • Use only lint-free cotton swabs. • Use only 99% pure isopropyl alcohol or an approved substitute. • Do not touch the electrodes.
Page 45
Press X/Y to change the screen and check the state of the lens surface on both the X- and Y-screens. Objective Lenses Figure 4 Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070...
Page 46
Clean the circular cleaving blade and clamp pads with a lint-free cotton swab soaked with isopropyl alcohol. Fiber Clamps (5) Cleaving Blade Figure 5 Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070...
1. Identify the field fiber type by consulting the fiber manufacturer’s data sheet. 2. Obtain an approximately 10 m length of fiber (same as field fiber). 3. Determine if this fiber type has a pre-programmed splicing profile in the 910FS. Use this profile for splicing.
Page 48
910FS Splicer Testing Splicing Splice-on Connectors (SOC) The 910FS can fusion splice SOC using the universal SOC adapters. Be sure to select the correct SOC to match the field fibers before splicing. The following procedure should be used to practice fusion splicing with SOC: 1.
900 μm field fiber. Use the 910CL to cleave the field fiber. Insert the fiber adapter with the cleaved fiber into the left-hand side of the 910FS fusion splicer. Make sure to butt the 900 μm buffer up to the edge of the fiber adapter. This will ensure that the mini splice sleeve will adhere to both sides of the 900 μm buffer.
Page 50
For SC connectors, install the outer housing onto the connector, being sure to align the angled corners of the inner housing with those of the outer housing (Figure 8). Greenlee / A Textron Company 4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070...
Page 51
910FS Splicer Figure 7 Figure 8 Compatibility Chart The Greenlee SOC adapter allows the Greenlee 900 micron SOC to be used in competitors’ fusion splicers. Manufacturer Sumitomo Fitel INNO Model FSM11 (S/M) FSM-17S FSM-18S Type-25e (U/S/M) S122(A/C/M/) IFS10 FSM-19S Type-39FH...
Page 52
Warranty Greenlee Textron Inc. warrants to the original purchaser of these goods for use that these products will be free from defects in workmanship and material for one year. This war- ranty is subject to the same terms and conditions contained in Greenlee Textron Inc.’s standard one-year limited warranty.