Door Trigger Error Chirp:
On: if the door trigger is active when arming, the horn/siren will emit an additional sound as an
alert notification
Off: an active door trigger when arming will not create an alert output
Door Lock Output:
0.8 seconds: the door lock output pulses will be 800ms in duration
3.5 seconds: the door lock pulses will be 3.5 seconds in duration
0.4 seconds: the door lock pulses will be 400ms in duration
Double Unlock (0.4 seconds): the unlock output only will pulse twice and will be 400ms in duration
Arm Defeat Polarity(for add-on security setting):
Positive: Arm defeat wire requires a positive pulse to defeat the arm operation
Negative: Arm defeat wire requires a negative pulse to defeat the arm operation
Note: in both options above the Ignition Override will also be functional
Disarm defeat polarity (for add-on security setting):
Positive: Disarm defeat wire requires a positive pulse to defeat the disarm operation
Negative: Disarm defeat wire requires a negative pulse to defeat the disarm operation
Sensor Add Arming Type (for sensor-add setting):
Active: requires same activation input on door motor wires as RKE security to arm the sensor
Passive: sensor arms by timer duration after the ignition is turned off and vehicle is exited.
Note: This feature does not apply to this system.
Flex Output 1:
Dome light: The output will turn on for 30 seconds (or until the ignition is turned on) each time the
system is disarmed. If on, it will turn off if the system state changes from disarmed to armed.
FAD (Factory Alarm Disarm): The output will pulse once for 800ms when disarming or activating
the trunk release. The disarm pulse will begin 500mS before the unlock or trunk release output
begins.
2nd unlock: The output will pulse for 800ms upon the 2nd Disarm command from a remote. It will
also pulse when ignition is turned off for ignition controlled unlocking; only if the user activated the
2nd unlock output prior to entering the vehicle.
FAT (Factory alarm trigger): The output will pulse once for 800ms when the on-board shock sensor
detects a full trigger. This setting is used when adding this system to a vehicle to trigger the factory
alarm.
Remote Start Report: The output will pulse once for 800ms when the
pressed OR when pressing the LOCK button on the OEM remote twice.
NOTE: when programmed for remote start report the
panic will be controlled by pressing the
Flex Output 2:
Dome light: The output will turn on for 30 seconds (or until the ignition is turned on) each time the
system is disarmed. If on, it will turn off if the system state changes disarmed to armed.
FAD (Factory Alarm Disarm): The output will pulse once for 800ms when disarming or activating
the trunk release. The disarm pulse will begin 500ms before the unlock or trunk release outputs
begin.
2nd unlock: The output will pulse for 800ms upon the 2nd Disarm command from a remote. It will
also pulse when ignition is turned off for ignition controlled unlocking; only if the user activated the
2nd unlock output prior to entering the vehicle.
FAT (Factory alarm trigger): The output will pulse once for 800ms when the on-board shock sensor
detects a full trigger. This setting is used when adding this system to a vehicle to trigger the factory
alarm.
Remote Start Report: The output will pulse once for 800ms when the button on the remote is
pressed OR when pressing the LOCK button on the OEM remote twice.
NOTE: when programmed for remote start report the
panic will be controlled by pressing the
© 2012 Directed. All rights reserved.
AUX
AUX
AUX
button will no longer control the panic feature,
button on the remote for 3 seconds.
A U X
AUX
AUX
button will no longer control the panic feature,
button on the remote for 3 seconds.
A U X
AUX
button on the remote is