11 Consideration must be given to the connection of the 
equipment to the supply circuit. Appropriate 
consideration of equipment nameplate ratings must be 
used when addressing this concern. Do not overload 
the circuit. 
12 Reliable grounding of rack‐mounted equipment must 
be maintained. Particular attention must be given to 
power supply connections other than direct 
connections to the branch circuits, such as power strips. 
13 The included power cord is approved for use only in 
specific countries or regions. Before using a power cord, 
verify that it is rated and approved for use in your 
location.
14 Minimum power cord rating for European Union (CE): 
Certified power supply cord not lighter than light PVC 
sheathed flexible cord according to IEC 60227, 
designation, or H05 VV‐F or H05 VVH2‐F2, and rated for 
at least 3G 0.75 mm². 
15 The following statement applies only to rack‐installed 
products that are GS‐Marked: This equipment is not 
intended for use at workplaces with visual display units, 
in accordance with §2 of the German ordinance for 
workplaces with visual display units.
16 When shipped from the factory, this SonicWall product 
has a single power supply installed. A second power 
supply can be ordered and installed for redundant AC 
power and added reliability. When the second power 
supply is installed:
• Both power cords must be removed to 
disconnect AC power from the unit.
• Always disconnect the power cords from the 
power supplies when installing or removing the 
power supply. Never install or remove a power 
supply with the AC power cord attached.
Lithium Battery Warning
The Lithium Battery used in the SonicWall internet security 
appliance may not be replaced by the user. The appliance must 
be returned to a SonicWall authorized service center for 
replacement with the same or equivalent type recommended 
by the manufacturer. If, for any reason, the battery or 
SonicWall security appliance must be disposed of, do so 
following the battery manufacturer's instructions.
Cable Connections
All Ethernet and RS232 (Console) cables are designed for intra‐
building connection to other equipment. Do not connect these 
SonicWall NSA 2650 Getting Started Guide