WARNING - Electric Shock Hazard. Can cause injury or death. Unit must be grounded in accordance with national and
local codes. The 4 pins in P6 have the potential of transferring up to 250 volts to the unit cabinet ground.
Designator
P6 - Pin 1
Tx
Inverter
P6 - Pin 2
Common
P6 - Pin 3
Rx
P6 - Pin 4
Inv 5V
LIQ
LIQ
AMB
AMB
COIL
COIL
Pump Down
L
C
XC20
Outdoor Control Terminal Designations and Input /Outputs
Description
Transmit data to inverter, connects to
Rx of inverter.
Inverter common
NOTE - This is a signal reference point
and not an earth ground.
Receive data from the inverter.
Connects to Tx of inverter.
Inverter 5VDC volts.
Liquid line temperature sensor sup
ply.
Liquid line temperature sensor return.
Outdoor ambient temperature sensor
supply.
Outdoor ambient temperature sensor
return.
Outdoor coil temperature sensor sup
ply.
Outdoor coil temperature sensor re
turn.
To initiate pump-down function, place jumper in
the ON position. (See PUMP-DOWN MODE
OPERATION on page 37.)
1. Place the jumper in the ON position to
activate pump-down mode.
2. Place the jumper in the OFF position to
deactivate pump-down mode.
NOTE -If the pump-down jumper is in the ON
position during power-up, it is ignored.
NOTE - The outdoor control stays in pump-down
mode for five minutes, after which the outdoor
control
initiates
a
compressor
sequence.
Load-shedding input
Load-shedding input reference. Refer
to wiring of load-shedding terminals
located on page 47.
Input
Outdoor control
communication
transmit pin.
Inverter common.
Outdoor control
communication
receive pin.
Inverter 5VDC volts
N/A
N/A
N/A
N/A
N/A
N/A
shutdown
24VAC input to L en
ergizes load shed
ding feature.
N/A
28
Output
•
Pin 1 to pin 2 should read 4.5 to 5.5
VDC when not communicating.
•
Pin 3 to pin 2 should read 4.5 to 5.5
VDC when not communicating.
•
Pin 4 to pin 2 should read 4.5 to 5.5
VDC.
NOTE - Communication signals switch off
and on rapidly. This may cause volt meter
readings to fluctuate.
Communication
signals
between this 5V and common (Pin 2).
N/A
N/A
N/A
N/A
N/A
N/A
ON
OFF
PUMP
PUMP
DOWN
DOWN
N/A
N/A
Common
This is normal.
will
switch
N/A
N/A
N/A
N/A
N/A
N/A
ON
OFF
N/A
24VAC
common