System overview
3.1
RFID systems
RFID systems from Siemens control and optimize material flow. They identify reliably,
quickly and economically, are insensitive to contamination and store data directly on the
product.
Identification
Frequency
system
RF300
13.56 MHz
MOBY D
13.56 MHz
MOBY E
13.56 MHz
MOBY I
1.81 MHz
3.2
SIMATIC RF300
3.2.1
RF300 system overview
SIMATIC RF300 is an inductive identification system specially designed for use in industrial
production for the control and optimization of material flow.
Thanks to its compact dimensions, RF300 is the obvious choice where installation conditions
are restricted, especially for assembly lines, handling systems and workpiece carrier
systems. RF300 is suitable for both simple and demanding RFID applications and it stands
out for its persuasive price/performance ratio.
SIMATIC RF300
System Manual, 11/2009 - Zwischenstand 17.09.2009, A5E01642529-04
Range,
Max.
max.
memory
0.2 m
20 byte
EEPROM,
64 KB
FRAM
0.8 m
112 byte
EEPROM
0,1 m
752 byte
EEPROM
0.15 m
32 KB
FRAM
Data transfer rate
Temperature,
(maximum) in
max.
byte/s
RF300 tags: 8000
Readers:
-25 °C to +70 °C
ISO tags:
Transponder:
- Read: 600
-40 °C to +85 °C
- Write: 400
+220 °C cyclic
- Read: 600
+ 85 °C or
+ 200 °C
- Write: 400
- Read: 400
+ 150 °C
- Write: 350
1250
+ 85 °C or
+ 220 °C cyclic
3
Special features
IQ-Sense interface
available;
integrated diagnostic
functions;
battery-free data
memory;
additional ISO 15693
functionality (RF310R,
340R, RF350R,
RF380R)
SmartLabels based on
ISO 15693
e.g. Tag-it/I-Code
Battery-free data
memory
Battery-free data
memory
15