Outdoor Pcb Circuit Diagram; Earth - Fujitsu ASU9RLS Service Manual

Split type room air conditioner wall mounted type
Hide thumbs Also See for ASU9RLS:
Table of Contents

Advertisement

OUTDOOR PCB CIRCUIT DIAGRAM

INVERTER ASSEMBLY
AOU9RLS : EZ-008KHUE
AOU12RLS : EZ-008LHUE
TO OUTDOOR UNIT
L
W103
1
UL1015 AWG20
BLACK
N
2
W100
SERIAL
UL1015 AWG20
3
WHITE
W102
UL1015 AWG20
POWER
4
W101
UL1015
SOURCE
AWG14
5
BLACK
TERMINAL BOARD
THERMISTOR ( PIPE TEMP. )
THERMISTOR ( DISCHARGE TEMP. )
THERMISTOR ( OUTDOOR TEMP. )
2009.01.15
F202
5A - 250V
UL1015 AWG14
BLACK
W1 B
UL1015 AWG14
WHITE
W2 B
UL1015 AWG20
RED
W4 B
BLACK
UL1015 AWG16
GREEN
W3 B
F201
20A - 250V

EARTH

1
BLACK
CN71
BLACK
2
B04B-PASK-1
BROWN
3
WHITE
BROWN
4
1
BLACK
CN70
2
B03B-PASK-1
WHITE
BLACK
3
REACTOR
UL3271
AWG14
RED
UL3271
AWG14
WHITE
W11
W10
W5
W6
B
B
INVERTER PCB ASSEMBLY
AOU9RLS : K06AX-0808HUE-C1
AOU12RLS : K06AX-0809HUE-C1
8
COMPRESSOR
U
UL3271 AWG16
RED
RED
B W7
V
UL3271 AWG16
WHITE
WHITE
B W8
W
UL3271 AWG16
BLACK
B W9
BLACK
1
BLACK
CN30
4-WAY VALVE
B2P3-VH-B-C
2
BLACK
3
BLACK
1
RED
DC FAN MOTOR
2
3
CN800
B5 ( 7 - 2.3 ) B-XASK-1-A
4
BLACK
F M
WHITE
5
WHITE
6
YELLOW
7
BROWN
1
RED
2
BROWN
CN40
3
BLUE
PMV
B6B-XARK-1-A
4
ORANGE
RED
5
YELLOW
6
WHITE
EXPANSION VALVE
C M

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Asu12rlsAou9rlsAou12rls