2-5. Inspecting Windows

The Windows inspection contains the following two types of inspection.
Audio
Modem
Before starting inspections, create a floppy disk from the service diag CD to be serviced.
The files to be used for inspection are stored in the following sub directory inside the CD. Copy all the files in the folder to the
floppy disk.
Audio
\windiag\wave
Modem
\windiag\modem
• Audio
A microphone and headphones are required for this inspection.
Double-click "t_auw01" icon (MS-DOS icon) in the floppy disk that is created in advance. The display of the DOS prompt
opens and the inspection starts. Once inspection starts, follow the instructions on the display to inspect the audio.
• Modem
A modem and a line simulator are required for this inspection.
Double-click "modem" icon (MS-DOS icon) in the floppy disk that is created in advance.
The display of the DOS prompt opens and the inspection starts.

2-6. Self diagnostics Change History

Date of issuance
2001/1
PCG-XG500
PCG-XG700
Confidential
PCG-XG500/XG700 (UC)
Model
Item
Announcement of change history starts.
2-1
" 1.Serial Port (COM) test " is added.
" 8.Mini Docking Station PCGA-PSX1 for Serial/Parallel Tests ",
" Serial/Parallel Tests " : Name and contents are changed.
" 9.DVD-ROM /CD-RW Bay supplied ", " DVD-ROM/CD-RW Tests"
: Name and contents are changed.
Serial Loopback Connector Diagram is added to [Reference].
2-2
" 1 Serial Loopback tool " is added.
" 7 PCG series for IrDA/IEEE1394 test " : Its contents and title of
illustration are changed.
" 9 CD-RW bay/DVD-ROM bay " : Its contents and title of illustration
are changed.