Test Operation - Fujitsu UTY-RNN*M series Installation Manual

Air conditioner remote controller (wired type)
Table of Contents

Advertisement

7) Heater room temperature correction
Depending on the installed environment, the room temperature sensor
may require a correction.
The settings may be changed as shown in the table below.
Setting Description
Standard
Lower control
Slightly warmer control
Warmer control
8) Auto restart
Enable or disable automatic system restart after a power outage.
Setting Description
Yes
No
* Auto restart is an emergency function such as for power failure etc.
Do not start and stop the indoor unit by this function in normal operation.
Be sure to operate by the control unit, or external input device.
9) Indoor room temperature sensor switching function
(Only for Wired remote controller)
The following settings are needed when use the control by Wired remote
controller temperature sensor.
Setting Description
No
Yes
* If setting value is "00" :
Room temperature is controlled by the indoor unit temperature sensor.
* If setting value is "01" :
Room temperature is controlled by either indoor unit temperature sensor
or remote controller unit sensor.
10) Remote controller signal code
Change the indoor unit Signal Code, depending on the remote controllers.
Setting Description
A
B
C
D
11) External input control
"Operation/Stop" mode or "Forced stop" mode can be elected.
Setting Description
Operation/Stop mode
(Setting forbidden)
Forced stop mode
12) Room temperature control switching
(Only for Wired remote controller)
This setting is used to set the room temperature control method when the
wired remote controller is selected by the Indoor room temperature sensor
switching function.
Setting Description
Control by the sensors of
both the indoor unit and the
wired remote controller.
Control only by the sensor of
the wired remote controller
En-7
(♦... Factory setting)
Function Number
Setting Value
00
01
31
02
03
(♦... Factory setting)
Function Number
Setting Value
00
40
01
(♦... Factory setting)
Function Number
Setting Value
00
42
01
(♦... Factory setting)
Function Number
Setting Value
00
01
44
02
03
(♦... Factory setting)
Function Number
Setting Value
00
46
01
02
(♦... Factory setting)
Function Number
Setting Value
00
48
01
13) Setting record
Record any changes to the settings in the following table.
Setting Description
Filter sign
Ceiling height
Outlet directions
Embedding the indoor unit
in a wall
Static pressure
Cooler room temperature
correction
Heater room temperature
correction
Auto restart
Indoor room temperature
sensor switching function
Remote controller signal code
External input control
Room temperature control
switching
After completing the FUNCTION SETTING, be sure to turn off the power
and turn it on again.

10. TEST OPERATION

(1) If the operation lamp is on, press the START/STOP button to turn it off.
(2) Press the "
" button and "
more than 2 seconds to start the test operation.
The operation lamp will light up and "
temperature display.
*
Perform the test operation for 60 minutes.
*
Pressing the START/STOP button will stop the test operation.
Setting Value
" button at the same time for
" will be displayed on the set
Test operation display

Advertisement

Table of Contents
loading