Nmea 0183 Device Connection - Simrad R2009 User Manual

Hide thumbs Also See for R2009:
Table of Contents

Advertisement

44

NMEA 0183 device connection

The NMEA 0183 serial port provides input (Listeners) and outputs (Talkers) for the various IEC
61162 interfaced sensors. The port uses the NMEA 0183 (serial balanced) standard, and can
be configured in the software for different baud rates up to 38,400 baud.
For configuring of the ports, refer to "Serial ports" on page 51.
The R2009 unit has one NMEA 0183 serial port, providing two inputs and two outputs.
Cable used: NMEA 0183 serial cable.
The R3016 unit has two The NMEA 0183 serial ports, providing four inputs and two
outputs. Cable used: NMEA 0183 High speed serial cable.
NMEA 0183 serial cable
Note:
R2009 only.
Cable labelled: 032-0080-08. Spare part number: 000-11247-001.
4
5
6
7
8
Unit socket (male)
Key
Port
Purpose
1
Port 2
Listener B (Rx+)
2
Port 2
Listener A (Rx-)
3
Port 2
Talker B (Tx+)
4
Port 2
Talker A (Tx-)
5
Port 1
Talker B (Tx+)
6
Port 1
Talker A (Tx-)
7
Port 1
Listener A (Rx-)
8
Port 1
Listener B (Rx+)
NMEA 0183 High speed serial cable
Note:
R3016 only.
Cable labelled: 032-0101-081. Spare part number: 000-12393-001.
Wiring
| R2009/R3016 User manual
3
2
2
1
4
3
5
6
1
7
8
Cable plug (female)
Color
Brown/White
Brown
Green/White
Green
Orange/White
Orange
Blue/White
Blue

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

R3016

Table of Contents