3-1. PREPARATION BEFORE
CONFIRMATION
Standard............................................................................. 135.3 ± 1 VAC
Check Condition:
AC input voltage: 120 (± 2) VAC
Note: If using a stabilized power supply, make sure that the distortion
factor is 3% or less.
Setting Mode: ............................................................................ Full mode
Signal Input: ............................................................Cross-hatch of NTSC
Initial Setting:.....................................................Standard Reset condition
Confi rm Point:............................Across CN5509 PIN 9 for B+ of D Board
3-1.1 HOLD-DOWN OPERATION
CONFIRMATION
1. Using an external DC power supply, apply 5.3 ± 0.5 Vdc between
Pin 2 of CN507 (jig connector) and ground (Pin 8); confi rm set goes
to hold-down (main power relay click).
2. Remove the external DC power supply.

SECTION 3: SAFETY RELATED ADJUSTMENTS

3-2. B+ MAX CONFIRMATION
Standard
135.3 ± 1 VAC
Check Condition:
AC input voltage: 120 (± 2) VAC
Note: If using a stabilized power supply, make sure that the distortion
factor is 3% or less.
Setting Mode: ............................................................................ Full mode
Signal Input: ............................................................Cross-hatch of NTSC
Initial Setting:.....................................................Standard Reset condition
Confi rm Point:............................Across CN5509 PIN 9 for B+ of D Board
— 21 —