Whirlpool WHAPSRO Installation And Operation Manual page 9

Reverse osmosis drinking water system
Table of Contents

Advertisement

Step B - Install RO Drain in Remote Location
Soft, Cold Water
Remote Installation
Location
IMPORTANT: Allow adequate open
space behind the
water filtration system
to avoid sharp bends
or kinks in the tubing.
Sump
1-1/2"
Air Gap
1-1/2"
Stand pipe
Air Gap
INSTALL A REMOTE DRAIN POINT
AND AIR GAP (Remote Location)
Route the drain tubing to an existing drain in the house.
A floor drain, laundry tub, standpipe, sump, etc. are
suitable drain points. See Fig. 11. This type of drain is
the preferred over the p-trap drain adapter.
Always be sure to provide a 1-1/2" air gap between the
end of the hose and the drain point. This will prevent
water from backing up into the system.
NOTE: Check your local plumbing codes.
Outside Faucet
(Hard Water)
Soft, Hot
Water
Water
Heater
1/4'' RED Tubing
1-1/2"
Air Gap
Laundry
Tub
Outside Faucet
(Hard Water)
Shutoff
Valve
Hard
Water to
House
Water
Softener
Tubing to
1-1/2"
Air Gap
Floor
FIG. 11
Drain
To install a remote drain point, complete the
following steps:
1. Locate the 1/4" red tubing on the Reverse Osmosis
filter assembly. See Fig. 10.
2. Determine if this length is long enough to reach the
drain point. Longer lengths of tubing (see parts list in
back of manual) may be needed.
3. If longer tubing is required, disconnect the 1/4" red
tubing and replace with an adequate length of tubing
to reach the drain point. Refer to Step F later in the
manual on how to disconnect and connect tubing.
NOTE: A flow control insert is located inside the
fitting that the drain tube connects to. See No. 12
on page 22. Leave this fitting in place.
4. Route the tubing to the drain point and secure at the
end with a bracket (not included). See Fig. 11.
Provide a 1-1/2" air gap between the end of the tube
and the drain. See Fig. 11.
9
BLUE Tubing
to Reverse
Osmosis Faucet
Soft Water -
GREEN Tubing
to Reverse
Osmosis System
Reverse Osmosis
System
Reverse Osmosis
Drain - RED
Tubing to Drain
YELLOW Tubing
to Storage Tank
Storage Tank
Water
Meter
Main Shutoff
Valve
RED
Drain
FIG. 10

Hide quick links:

Advertisement

Table of Contents
loading